dc.description.abstractThe thermal history of a material with initially filled trap states may be probed using thermoluminescence. Since luminescent microparticles are composed of robust oxides, they are viable candidates for sensing temperature under conditions where all other types of direct-contact sensors fail. Mg(2)SiO(4) : Tb, Co particles with two thermoluminescent peaks have been heated using micromachined heaters over a 232 degrees C to 313 degrees C range on time scales of less than 200 ms. The effect of maximum temperature during excitation on the intensity ratio of the two luminescent peaks has been compared with first-order kinetics theory and shown to match within an average error of 4.4%.en
dc.relationDefense Threat Reduction Agency [HDTRA1-07-1-0016]
dc.rightsrestrictedAccessen
dc.sourceIEEE Sensors Journalen
dc.subjectMicroelectromechanical devicesen
dc.subjecttemperature measurementen
dc.subjectthermal historyen
dc.subjectthermoluminescence (TL)en
dc.titleMeasurement of Rapid Temperature Profiles Using Thermoluminescent Microparticlesen
dc.typearticleen
dcterms.abstractYукихара, Едуардо Г.; Мах, Мерлин Л.; Манфред, Мицхаел Е.; Ким, Сангхо С.; Прокиц, Мирјана; Талгхадер, Јосепх Ј.;
dc.citation.volume10
dc.citation.issue2
dc.citation.spage311
dc.citation.epage315
dc.identifier.wos000273135800013
dc.identifier.doi10.1109/JSEN.2009.2034023
dc.citation.rankM22