Radiation sensing MOSFETs (RADFETs) have found numerous applications in space research, as well as in nuclear technology and research, and radiotherapy. Since proton irradiation is an essential part of the space radiation environment, it is important to know RADFET proton response precisely. In this work a numerical simulation of RADFET proton response is performed. To this end the proton transport Monte Carlo software SRNA-2K5, developed by one of the authors, has been adapted to obtain the energy deposited in the RADFET structure and dose distribution within the microscopic dimensions of the dosimeter sensitive volume. Our results show that RADFET response to proton irradiation depends significantly of packaging configurations with kovar lid.
Ključne reči:
RADFET / kovar lid / proton irradiation / SRNA-2K5Izvor:
Nuclear technology and radiation protection, 2008, 23, 1, 37-40
DOI: 10.2298/NTRP0801037S
ISSN: 1451-3994
WoS: 000259982900005
Scopus: 2-s2.0-77955605974
Kolekcije
Institucija/grupa
VinčaTY - JOUR AU - Stanković, Srboljub AU - Ilić, Radovan D. AU - Davidović, Miloš D. AU - Kovačević, Milojko AU - Davidović, Dragomir PY - 2008 UR - https://vinar.vin.bg.ac.rs/handle/123456789/3541 AB - Radiation sensing MOSFETs (RADFETs) have found numerous applications in space research, as well as in nuclear technology and research, and radiotherapy. Since proton irradiation is an essential part of the space radiation environment, it is important to know RADFET proton response precisely. In this work a numerical simulation of RADFET proton response is performed. To this end the proton transport Monte Carlo software SRNA-2K5, developed by one of the authors, has been adapted to obtain the energy deposited in the RADFET structure and dose distribution within the microscopic dimensions of the dosimeter sensitive volume. Our results show that RADFET response to proton irradiation depends significantly of packaging configurations with kovar lid. T2 - Nuclear technology and radiation protection T1 - Influence of Packaging Configuration with Kovar Lid on Radfet Response to Proton Irradiation VL - 23 IS - 1 SP - 37 EP - 40 DO - 10.2298/NTRP0801037S ER -
@article{ author = "Stanković, Srboljub and Ilić, Radovan D. and Davidović, Miloš D. and Kovačević, Milojko and Davidović, Dragomir", year = "2008", abstract = "Radiation sensing MOSFETs (RADFETs) have found numerous applications in space research, as well as in nuclear technology and research, and radiotherapy. Since proton irradiation is an essential part of the space radiation environment, it is important to know RADFET proton response precisely. In this work a numerical simulation of RADFET proton response is performed. To this end the proton transport Monte Carlo software SRNA-2K5, developed by one of the authors, has been adapted to obtain the energy deposited in the RADFET structure and dose distribution within the microscopic dimensions of the dosimeter sensitive volume. Our results show that RADFET response to proton irradiation depends significantly of packaging configurations with kovar lid.", journal = "Nuclear technology and radiation protection", title = "Influence of Packaging Configuration with Kovar Lid on Radfet Response to Proton Irradiation", volume = "23", number = "1", pages = "37-40", doi = "10.2298/NTRP0801037S" }
Stanković, S., Ilić, R. D., Davidović, M. D., Kovačević, M.,& Davidović, D.. (2008). Influence of Packaging Configuration with Kovar Lid on Radfet Response to Proton Irradiation. in Nuclear technology and radiation protection, 23(1), 37-40. https://doi.org/10.2298/NTRP0801037S
Stanković S, Ilić RD, Davidović MD, Kovačević M, Davidović D. Influence of Packaging Configuration with Kovar Lid on Radfet Response to Proton Irradiation. in Nuclear technology and radiation protection. 2008;23(1):37-40. doi:10.2298/NTRP0801037S .
Stanković, Srboljub, Ilić, Radovan D., Davidović, Miloš D., Kovačević, Milojko, Davidović, Dragomir, "Influence of Packaging Configuration with Kovar Lid on Radfet Response to Proton Irradiation" in Nuclear technology and radiation protection, 23, no. 1 (2008):37-40, https://doi.org/10.2298/NTRP0801037S . .