A spectroscopic investigation of spatial symmetry of radiation in the U-shaped DC argon plasma with aerosol supply
Nema prikaza
Autori
Savović, JelenaKuzmanović, Miroslav M.
Pavlović, Mirjana S.
Stoiljković, Milovan
Rankovic, D. P.
Marinković, Miloš
Članak u časopisu
Metapodaci
Prikaz svih podataka o dokumentuApstrakt
Radial distributions of plasma parameters, temperature, and electron number density, together with radial distribution of analyte absorption and emission, were investigated in order to obtain insight into the radial symmetry of low-current ( LT = 10A), atmospheric pressure, argon stabilized arc with tangential introduction of the aerosol. For plasma diagnostics, several methods were used: measurements of H line profile, absolute intensity measurements of the argon 430.01-nm line, and of the spectrally adjacent continuum and power interruption technique. It was found that the inevitable asymmetry in aerosol introduction has negligible influence on basic plasma parameters but influences considerably the spatial distribution of the analyte particle spectral absorption and emission.
Ključne reči:
argon plasma / DC arc / plasma diagnostics / radial symmetryIzvor:
Spectroscopy Letters, 2008, 41, 4, 166-173
DOI: 10.1080/00387010802132326
ISSN: 0038-7010
WoS: 000257028300004
Scopus: 2-s2.0-45749115805
Kolekcije
Institucija/grupa
VinčaTY - JOUR AU - Savović, Jelena AU - Kuzmanović, Miroslav M. AU - Pavlović, Mirjana S. AU - Stoiljković, Milovan AU - Rankovic, D. P. AU - Marinković, Miloš PY - 2008 UR - https://vinar.vin.bg.ac.rs/handle/123456789/3471 AB - Radial distributions of plasma parameters, temperature, and electron number density, together with radial distribution of analyte absorption and emission, were investigated in order to obtain insight into the radial symmetry of low-current ( LT = 10A), atmospheric pressure, argon stabilized arc with tangential introduction of the aerosol. For plasma diagnostics, several methods were used: measurements of H line profile, absolute intensity measurements of the argon 430.01-nm line, and of the spectrally adjacent continuum and power interruption technique. It was found that the inevitable asymmetry in aerosol introduction has negligible influence on basic plasma parameters but influences considerably the spatial distribution of the analyte particle spectral absorption and emission. T2 - Spectroscopy Letters T1 - A spectroscopic investigation of spatial symmetry of radiation in the U-shaped DC argon plasma with aerosol supply VL - 41 IS - 4 SP - 166 EP - 173 DO - 10.1080/00387010802132326 ER -
@article{ author = "Savović, Jelena and Kuzmanović, Miroslav M. and Pavlović, Mirjana S. and Stoiljković, Milovan and Rankovic, D. P. and Marinković, Miloš", year = "2008", abstract = "Radial distributions of plasma parameters, temperature, and electron number density, together with radial distribution of analyte absorption and emission, were investigated in order to obtain insight into the radial symmetry of low-current ( LT = 10A), atmospheric pressure, argon stabilized arc with tangential introduction of the aerosol. For plasma diagnostics, several methods were used: measurements of H line profile, absolute intensity measurements of the argon 430.01-nm line, and of the spectrally adjacent continuum and power interruption technique. It was found that the inevitable asymmetry in aerosol introduction has negligible influence on basic plasma parameters but influences considerably the spatial distribution of the analyte particle spectral absorption and emission.", journal = "Spectroscopy Letters", title = "A spectroscopic investigation of spatial symmetry of radiation in the U-shaped DC argon plasma with aerosol supply", volume = "41", number = "4", pages = "166-173", doi = "10.1080/00387010802132326" }
Savović, J., Kuzmanović, M. M., Pavlović, M. S., Stoiljković, M., Rankovic, D. P.,& Marinković, M.. (2008). A spectroscopic investigation of spatial symmetry of radiation in the U-shaped DC argon plasma with aerosol supply. in Spectroscopy Letters, 41(4), 166-173. https://doi.org/10.1080/00387010802132326
Savović J, Kuzmanović MM, Pavlović MS, Stoiljković M, Rankovic DP, Marinković M. A spectroscopic investigation of spatial symmetry of radiation in the U-shaped DC argon plasma with aerosol supply. in Spectroscopy Letters. 2008;41(4):166-173. doi:10.1080/00387010802132326 .
Savović, Jelena, Kuzmanović, Miroslav M., Pavlović, Mirjana S., Stoiljković, Milovan, Rankovic, D. P., Marinković, Miloš, "A spectroscopic investigation of spatial symmetry of radiation in the U-shaped DC argon plasma with aerosol supply" in Spectroscopy Letters, 41, no. 4 (2008):166-173, https://doi.org/10.1080/00387010802132326 . .