Indirect determination of lutetium by differential pulse anodic stripping voltammetry at a hanging mercury drop electrode
Апстракт
Lutetium has been determined by differential pulse anodic stripping voltammetry in an acidic solution containing Zn-EDTA. Lutetium (III) ions liberated zinc (II), which was preconcentrated on a hanging mercury drop electrode and stripped anodically, resulting in peak current linearly dependent on lutetium (III) concentration. Less than 0.4 ng mL(-1) lutetium could be detected after a 2 min deposition.
Кључне речи:
lutetium / Zn-EDTA complex / indirect determination / differential pulse anodic stripping voltammetryИзвор:
Central European Journal of Chemistry, 2008, 6, 1, 65-69
DOI: 10.2478/s11532-007-0055-3
ISSN: 1895-1066
WoS: 000252467300009
Scopus: 2-s2.0-38549103112
Колекције
Институција/група
VinčaTY - JOUR AU - Kumrić, Ksenija AU - Trtić-Petrović, Tatjana M. AU - Ignjatović, Ljubiša M. AU - Čomor, Jožef J. PY - 2008 UR - https://vinar.vin.bg.ac.rs/handle/123456789/3348 AB - Lutetium has been determined by differential pulse anodic stripping voltammetry in an acidic solution containing Zn-EDTA. Lutetium (III) ions liberated zinc (II), which was preconcentrated on a hanging mercury drop electrode and stripped anodically, resulting in peak current linearly dependent on lutetium (III) concentration. Less than 0.4 ng mL(-1) lutetium could be detected after a 2 min deposition. T2 - Central European Journal of Chemistry T1 - Indirect determination of lutetium by differential pulse anodic stripping voltammetry at a hanging mercury drop electrode VL - 6 IS - 1 SP - 65 EP - 69 DO - 10.2478/s11532-007-0055-3 ER -
@article{ author = "Kumrić, Ksenija and Trtić-Petrović, Tatjana M. and Ignjatović, Ljubiša M. and Čomor, Jožef J.", year = "2008", abstract = "Lutetium has been determined by differential pulse anodic stripping voltammetry in an acidic solution containing Zn-EDTA. Lutetium (III) ions liberated zinc (II), which was preconcentrated on a hanging mercury drop electrode and stripped anodically, resulting in peak current linearly dependent on lutetium (III) concentration. Less than 0.4 ng mL(-1) lutetium could be detected after a 2 min deposition.", journal = "Central European Journal of Chemistry", title = "Indirect determination of lutetium by differential pulse anodic stripping voltammetry at a hanging mercury drop electrode", volume = "6", number = "1", pages = "65-69", doi = "10.2478/s11532-007-0055-3" }
Kumrić, K., Trtić-Petrović, T. M., Ignjatović, L. M.,& Čomor, J. J.. (2008). Indirect determination of lutetium by differential pulse anodic stripping voltammetry at a hanging mercury drop electrode. in Central European Journal of Chemistry, 6(1), 65-69. https://doi.org/10.2478/s11532-007-0055-3
Kumrić K, Trtić-Petrović TM, Ignjatović LM, Čomor JJ. Indirect determination of lutetium by differential pulse anodic stripping voltammetry at a hanging mercury drop electrode. in Central European Journal of Chemistry. 2008;6(1):65-69. doi:10.2478/s11532-007-0055-3 .
Kumrić, Ksenija, Trtić-Petrović, Tatjana M., Ignjatović, Ljubiša M., Čomor, Jožef J., "Indirect determination of lutetium by differential pulse anodic stripping voltammetry at a hanging mercury drop electrode" in Central European Journal of Chemistry, 6, no. 1 (2008):65-69, https://doi.org/10.2478/s11532-007-0055-3 . .