Приказ основних података о документу

dc.creatorVukanac, Ivana
dc.creatorNovković, Dušan N.
dc.creatorKandić, Aleksandar
dc.creatorNađđerđ, Laslo
dc.date.accessioned2018-03-01T19:35:45Z
dc.date.available2018-03-01T19:35:45Z
dc.date.issued2005
dc.identifier.issn1350-4487
dc.identifier.urihttps://vinar.vin.bg.ac.rs/handle/123456789/2861
dc.description.abstractThe content of impurities in gold foils intended for neutron flux measurements has been determined. The gold foils were irradiated by a high neutron flux and the activities of the activated impurities were measured after a cooling period of 48 days by a HPGe spectrometer. The activated impurities were Zn and Ag, and their content was determined from the measured activities ratio of the isotopes Zn-65 and Ag-110m to Au-198. The activated isotopes have longer half-lives than Au-198 and they could be measured after the cooling period. (C) 2004 Elsevier Ltd. All rights reserved.en
dc.rightsrestrictedAccessen
dc.sourceRadiation Measurementsen
dc.subjectactivation detectoren
dc.subjectgold foilen
dc.subjectactivation analysisen
dc.titleDetermination of impurity content in gold foilsen
dc.typearticleen
dcterms.abstractНовковиц, Д; Вуканац Ивана; Кандић Aлександар; Наддерд Ласло;
dc.citation.volume39
dc.citation.issue4
dc.citation.spage417
dc.citation.epage420
dc.identifier.wos000227134100008
dc.identifier.doi10.1016/j.radmeas.2004.06.007
dc.citation.rankM21
dc.identifier.scopus2-s2.0-13444274389


Документи

ДатотекеВеличинаФорматПреглед

Уз овај запис нема датотека.

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу