Determination of impurity content in gold foils
Apstrakt
The content of impurities in gold foils intended for neutron flux measurements has been determined. The gold foils were irradiated by a high neutron flux and the activities of the activated impurities were measured after a cooling period of 48 days by a HPGe spectrometer. The activated impurities were Zn and Ag, and their content was determined from the measured activities ratio of the isotopes Zn-65 and Ag-110m to Au-198. The activated isotopes have longer half-lives than Au-198 and they could be measured after the cooling period. (C) 2004 Elsevier Ltd. All rights reserved.
Ključne reči:
activation detector / gold foil / activation analysisIzvor:
Radiation Measurements, 2005, 39, 4, 417-420
DOI: 10.1016/j.radmeas.2004.06.007
ISSN: 1350-4487
WoS: 000227134100008
Scopus: 2-s2.0-13444274389
Kolekcije
Institucija/grupa
VinčaTY - JOUR AU - Vukanac, Ivana AU - Novković, Dušan N. AU - Kandić, Aleksandar AU - Nađđerđ, Laslo PY - 2005 UR - https://vinar.vin.bg.ac.rs/handle/123456789/2861 AB - The content of impurities in gold foils intended for neutron flux measurements has been determined. The gold foils were irradiated by a high neutron flux and the activities of the activated impurities were measured after a cooling period of 48 days by a HPGe spectrometer. The activated impurities were Zn and Ag, and their content was determined from the measured activities ratio of the isotopes Zn-65 and Ag-110m to Au-198. The activated isotopes have longer half-lives than Au-198 and they could be measured after the cooling period. (C) 2004 Elsevier Ltd. All rights reserved. T2 - Radiation Measurements T1 - Determination of impurity content in gold foils VL - 39 IS - 4 SP - 417 EP - 420 DO - 10.1016/j.radmeas.2004.06.007 ER -
@article{ author = "Vukanac, Ivana and Novković, Dušan N. and Kandić, Aleksandar and Nađđerđ, Laslo", year = "2005", abstract = "The content of impurities in gold foils intended for neutron flux measurements has been determined. The gold foils were irradiated by a high neutron flux and the activities of the activated impurities were measured after a cooling period of 48 days by a HPGe spectrometer. The activated impurities were Zn and Ag, and their content was determined from the measured activities ratio of the isotopes Zn-65 and Ag-110m to Au-198. The activated isotopes have longer half-lives than Au-198 and they could be measured after the cooling period. (C) 2004 Elsevier Ltd. All rights reserved.", journal = "Radiation Measurements", title = "Determination of impurity content in gold foils", volume = "39", number = "4", pages = "417-420", doi = "10.1016/j.radmeas.2004.06.007" }
Vukanac, I., Novković, D. N., Kandić, A.,& Nađđerđ, L.. (2005). Determination of impurity content in gold foils. in Radiation Measurements, 39(4), 417-420. https://doi.org/10.1016/j.radmeas.2004.06.007
Vukanac I, Novković DN, Kandić A, Nađđerđ L. Determination of impurity content in gold foils. in Radiation Measurements. 2005;39(4):417-420. doi:10.1016/j.radmeas.2004.06.007 .
Vukanac, Ivana, Novković, Dušan N., Kandić, Aleksandar, Nađđerđ, Laslo, "Determination of impurity content in gold foils" in Radiation Measurements, 39, no. 4 (2005):417-420, https://doi.org/10.1016/j.radmeas.2004.06.007 . .