Introduction of Marinelli effective solid angles for correcting the calibration of NaI(Tl) field gamma-ray spectrometry in TL/OSL dating
Nema prikaza
Autori
De Corte, FHossain, SM
Jovanović, S.
Dlabac, A
De Wispelaere, A
Vandenberghe, D
Van de Haute, P
Članak u časopisu
Metapodaci
Prikaz svih podataka o dokumentuApstrakt
A study is made of the corrections that are needed in the evaluation of the annual radiation dose, for use in TL/OSL-dating, via NaI(Tl) field gamma-ray spectrometry (monitoring of K, Th and U), calibrated via voluminous blocks that are simulating the Auger hole measuring conditions. Two cases are considered: the Heidelberg granite calibration block, which was found to be quasi-infinite, and the Oxford concrete calibration blocks, for which effective concentrations of elements are reported so as to account for their non-infiniteness. The calculations, via the software package ANGLE, are based on the concept of effective solid angles for Marinelli geometries.
Izvor:
Journal of Radioanalytical and Nuclear Chemistry, 2003, 257, 3, 551-555
DOI: 10.1023/A:1025436430824
ISSN: 0236-5731
WoS: 000184915000017
Scopus: 2-s2.0-0141635226
Kolekcije
Institucija/grupa
VinčaTY - JOUR AU - De Corte, F AU - Hossain, SM AU - Jovanović, S. AU - Dlabac, A AU - De Wispelaere, A AU - Vandenberghe, D AU - Van de Haute, P PY - 2003 UR - https://vinar.vin.bg.ac.rs/handle/123456789/2656 AB - A study is made of the corrections that are needed in the evaluation of the annual radiation dose, for use in TL/OSL-dating, via NaI(Tl) field gamma-ray spectrometry (monitoring of K, Th and U), calibrated via voluminous blocks that are simulating the Auger hole measuring conditions. Two cases are considered: the Heidelberg granite calibration block, which was found to be quasi-infinite, and the Oxford concrete calibration blocks, for which effective concentrations of elements are reported so as to account for their non-infiniteness. The calculations, via the software package ANGLE, are based on the concept of effective solid angles for Marinelli geometries. T2 - Journal of Radioanalytical and Nuclear Chemistry T1 - Introduction of Marinelli effective solid angles for correcting the calibration of NaI(Tl) field gamma-ray spectrometry in TL/OSL dating VL - 257 IS - 3 SP - 551 EP - 555 DO - 10.1023/A:1025436430824 ER -
@article{ author = "De Corte, F and Hossain, SM and Jovanović, S. and Dlabac, A and De Wispelaere, A and Vandenberghe, D and Van de Haute, P", year = "2003", abstract = "A study is made of the corrections that are needed in the evaluation of the annual radiation dose, for use in TL/OSL-dating, via NaI(Tl) field gamma-ray spectrometry (monitoring of K, Th and U), calibrated via voluminous blocks that are simulating the Auger hole measuring conditions. Two cases are considered: the Heidelberg granite calibration block, which was found to be quasi-infinite, and the Oxford concrete calibration blocks, for which effective concentrations of elements are reported so as to account for their non-infiniteness. The calculations, via the software package ANGLE, are based on the concept of effective solid angles for Marinelli geometries.", journal = "Journal of Radioanalytical and Nuclear Chemistry", title = "Introduction of Marinelli effective solid angles for correcting the calibration of NaI(Tl) field gamma-ray spectrometry in TL/OSL dating", volume = "257", number = "3", pages = "551-555", doi = "10.1023/A:1025436430824" }
De Corte, F., Hossain, S., Jovanović, S., Dlabac, A., De Wispelaere, A., Vandenberghe, D.,& Van de Haute, P.. (2003). Introduction of Marinelli effective solid angles for correcting the calibration of NaI(Tl) field gamma-ray spectrometry in TL/OSL dating. in Journal of Radioanalytical and Nuclear Chemistry, 257(3), 551-555. https://doi.org/10.1023/A:1025436430824
De Corte F, Hossain S, Jovanović S, Dlabac A, De Wispelaere A, Vandenberghe D, Van de Haute P. Introduction of Marinelli effective solid angles for correcting the calibration of NaI(Tl) field gamma-ray spectrometry in TL/OSL dating. in Journal of Radioanalytical and Nuclear Chemistry. 2003;257(3):551-555. doi:10.1023/A:1025436430824 .
De Corte, F, Hossain, SM, Jovanović, S., Dlabac, A, De Wispelaere, A, Vandenberghe, D, Van de Haute, P, "Introduction of Marinelli effective solid angles for correcting the calibration of NaI(Tl) field gamma-ray spectrometry in TL/OSL dating" in Journal of Radioanalytical and Nuclear Chemistry, 257, no. 3 (2003):551-555, https://doi.org/10.1023/A:1025436430824 . .