Приказ основних података о документу

dc.creatorVučina, Jurij L.
dc.creatorMarković, Mirjana
dc.creatorKukoč, A. H.
dc.date.accessioned2018-03-01T18:11:30Z
dc.date.available2018-03-01T18:11:30Z
dc.date.issued1996
dc.identifier.issn0236-5731
dc.identifier.urihttps://vinar.vin.bg.ac.rs/handle/123456789/1966
dc.description.abstractThe long-lived gamma-radionuclidic impurities in the columns of spent Mo-99/Tc-99m generators one year after the calibration date have been determined by v-spectrometry. Three radionuclidic impurities fission products (Ru-103, Ru-106 and Sb-125) were detected. Also in the majority of samples, three radioisotopes of tungsten (W-181, W-185 and W-188) were also present. The contents of the impurities were found to vary,greatly. According to the activity, energy and half-life, the main contribution to the residual activity in the spent generators is due to the presence of Sb-125.en
dc.rightsrestrictedAccessen
dc.sourceJournal of Radioanalytical and Nuclear Chemistry - Lettersen
dc.titleLong-lived gamma-radionuclidic impurities in spent Mo-99/Tc-99m generatorsen
dc.typearticleen
dc.rights.licenseARR
dcterms.abstractВуцина, ЈЛ; Марковић Мирјана; Кукоц, AХ;
dc.citation.volume212
dc.citation.issue3
dc.citation.spage221
dc.citation.epage227
dc.identifier.wosA1996UB50000006
dc.identifier.doi10.1007/BF02162229
dc.type.versionpublishedVersion
dc.identifier.scopus2-s2.0-0029998803


Документи

ДатотекеВеличинаФорматПреглед

Уз овај запис нема датотека.

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу