Comparison of radon doses based on different radon monitoring approaches
Само за регистроване кориснике
2017
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
In 43 places (23 schools, 3 kindergartens, 16 offices and one dwelling), indoor radon has been monitored as an intercomparison experiment, using alpha-scintillation cells (SC - Joief Stefan Institute, Slovenia), various kinds of solid state nuclear track detectors (KIK - Karlsruhe Institute of Technology, Germany; UFO - National Institute of Radiological Sciences, Chiba, Japan; RET - University College Dublin, Ireland) and active electronic devices (EQF, Sarad, Germany). At the same place, the radon levels and, consequently, the effective doses obtained with different radon devices differed substantially (by a factor of 2 or more), and no regularity was observed as regards which detector would show a higher or lower dose. (C) 2016 Elsevier Ltd. All rights reserved.
Кључне речи:
Radon / Indoor air / Solid state nuclear track detectors / Retrospective detectors / Continuous electronic devices / Intercomparison / Dose estimates / Assessment of dose differencesИзвор:
Journal of Environmental Radioactivity, 2017, 169, 19-26Финансирање / пројекти:
- Slovenian Research Agency [P1-0143, BI-SC/04-05-002]
DOI: 10.1016/j.jenvrad.2016.11.023
ISSN: 0265-931X; 1879-1700
PubMed: 28040622
WoS: 000398752300003
Scopus: 2-s2.0-85007425656
Колекције
Институција/група
VinčaTY - JOUR AU - Vaupotič, Janja AU - Smrekar, Natasa AU - Žunić, Zora S. PY - 2017 UR - https://vinar.vin.bg.ac.rs/handle/123456789/1502 AB - In 43 places (23 schools, 3 kindergartens, 16 offices and one dwelling), indoor radon has been monitored as an intercomparison experiment, using alpha-scintillation cells (SC - Joief Stefan Institute, Slovenia), various kinds of solid state nuclear track detectors (KIK - Karlsruhe Institute of Technology, Germany; UFO - National Institute of Radiological Sciences, Chiba, Japan; RET - University College Dublin, Ireland) and active electronic devices (EQF, Sarad, Germany). At the same place, the radon levels and, consequently, the effective doses obtained with different radon devices differed substantially (by a factor of 2 or more), and no regularity was observed as regards which detector would show a higher or lower dose. (C) 2016 Elsevier Ltd. All rights reserved. T2 - Journal of Environmental Radioactivity T1 - Comparison of radon doses based on different radon monitoring approaches VL - 169 SP - 19 EP - 26 DO - 10.1016/j.jenvrad.2016.11.023 ER -
@article{ author = "Vaupotič, Janja and Smrekar, Natasa and Žunić, Zora S.", year = "2017", abstract = "In 43 places (23 schools, 3 kindergartens, 16 offices and one dwelling), indoor radon has been monitored as an intercomparison experiment, using alpha-scintillation cells (SC - Joief Stefan Institute, Slovenia), various kinds of solid state nuclear track detectors (KIK - Karlsruhe Institute of Technology, Germany; UFO - National Institute of Radiological Sciences, Chiba, Japan; RET - University College Dublin, Ireland) and active electronic devices (EQF, Sarad, Germany). At the same place, the radon levels and, consequently, the effective doses obtained with different radon devices differed substantially (by a factor of 2 or more), and no regularity was observed as regards which detector would show a higher or lower dose. (C) 2016 Elsevier Ltd. All rights reserved.", journal = "Journal of Environmental Radioactivity", title = "Comparison of radon doses based on different radon monitoring approaches", volume = "169", pages = "19-26", doi = "10.1016/j.jenvrad.2016.11.023" }
Vaupotič, J., Smrekar, N.,& Žunić, Z. S.. (2017). Comparison of radon doses based on different radon monitoring approaches. in Journal of Environmental Radioactivity, 169, 19-26. https://doi.org/10.1016/j.jenvrad.2016.11.023
Vaupotič J, Smrekar N, Žunić ZS. Comparison of radon doses based on different radon monitoring approaches. in Journal of Environmental Radioactivity. 2017;169:19-26. doi:10.1016/j.jenvrad.2016.11.023 .
Vaupotič, Janja, Smrekar, Natasa, Žunić, Zora S., "Comparison of radon doses based on different radon monitoring approaches" in Journal of Environmental Radioactivity, 169 (2017):19-26, https://doi.org/10.1016/j.jenvrad.2016.11.023 . .