Evaluaton of dose rate data provided by non-governmental networks
Аутори
Živanović, MilošKržanović, Nikola
Iurlaro, Giorgia
Bell, Steven
Morosh, Viacheslav
Đaletić, Miloš
Pantelić, Gordana
Конференцијски прилог (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
In recent years, the number of non-governmental networks providing quasi real time dose rates is growing. This data is available to the general public via open access based platforms on the internet. The research on the non-governmental networks is scarce and the measurements represented there are mostly carried out using broadly available commercial simple hand-held devices. Without proper testing of these devices in metrological laboratories, there is a significant possibility for discrepancies between the official and non-governmental data, which may have wider implications. Within project 16ENV04 Preparedness, a systematic study of non-governmental networks produced a list of 16 types of dosimeters that are commonly used. Four dosimeters of each type were sourced and commissioned by project partners and are currently undergoing the testing. Test procedures are shortly described in this paper and preliminary results for 2 types of dosimeters are presented.
Извор:
30. симпозијум ДЗЗСЦГ : зборник радова, 2019, 297-302Издавач:
- Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе
Напомена:
- XXX симпозијум ДЗЗСЦГ (Друштва за заштиту од зрачења Србије и Црне Горе), 2-4. октобар 2019. године
Колекције
Институција/група
VinčaTY - CONF AU - Živanović, Miloš AU - Kržanović, Nikola AU - Iurlaro, Giorgia AU - Bell, Steven AU - Morosh, Viacheslav AU - Đaletić, Miloš AU - Pantelić, Gordana PY - 2019 UR - https://vinar.vin.bg.ac.rs/handle/123456789/11922 AB - In recent years, the number of non-governmental networks providing quasi real time dose rates is growing. This data is available to the general public via open access based platforms on the internet. The research on the non-governmental networks is scarce and the measurements represented there are mostly carried out using broadly available commercial simple hand-held devices. Without proper testing of these devices in metrological laboratories, there is a significant possibility for discrepancies between the official and non-governmental data, which may have wider implications. Within project 16ENV04 Preparedness, a systematic study of non-governmental networks produced a list of 16 types of dosimeters that are commonly used. Four dosimeters of each type were sourced and commissioned by project partners and are currently undergoing the testing. Test procedures are shortly described in this paper and preliminary results for 2 types of dosimeters are presented. PB - Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе C3 - 30. симпозијум ДЗЗСЦГ : зборник радова T1 - Evaluaton of dose rate data provided by non-governmental networks SP - 297 EP - 302 UR - https://hdl.handle.net/21.15107/rcub_vinar_11922 ER -
@conference{ author = "Živanović, Miloš and Kržanović, Nikola and Iurlaro, Giorgia and Bell, Steven and Morosh, Viacheslav and Đaletić, Miloš and Pantelić, Gordana", year = "2019", abstract = "In recent years, the number of non-governmental networks providing quasi real time dose rates is growing. This data is available to the general public via open access based platforms on the internet. The research on the non-governmental networks is scarce and the measurements represented there are mostly carried out using broadly available commercial simple hand-held devices. Without proper testing of these devices in metrological laboratories, there is a significant possibility for discrepancies between the official and non-governmental data, which may have wider implications. Within project 16ENV04 Preparedness, a systematic study of non-governmental networks produced a list of 16 types of dosimeters that are commonly used. Four dosimeters of each type were sourced and commissioned by project partners and are currently undergoing the testing. Test procedures are shortly described in this paper and preliminary results for 2 types of dosimeters are presented.", publisher = "Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе", journal = "30. симпозијум ДЗЗСЦГ : зборник радова", title = "Evaluaton of dose rate data provided by non-governmental networks", pages = "297-302", url = "https://hdl.handle.net/21.15107/rcub_vinar_11922" }
Živanović, M., Kržanović, N., Iurlaro, G., Bell, S., Morosh, V., Đaletić, M.,& Pantelić, G.. (2019). Evaluaton of dose rate data provided by non-governmental networks. in 30. симпозијум ДЗЗСЦГ : зборник радова Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе., 297-302. https://hdl.handle.net/21.15107/rcub_vinar_11922
Živanović M, Kržanović N, Iurlaro G, Bell S, Morosh V, Đaletić M, Pantelić G. Evaluaton of dose rate data provided by non-governmental networks. in 30. симпозијум ДЗЗСЦГ : зборник радова. 2019;:297-302. https://hdl.handle.net/21.15107/rcub_vinar_11922 .
Živanović, Miloš, Kržanović, Nikola, Iurlaro, Giorgia, Bell, Steven, Morosh, Viacheslav, Đaletić, Miloš, Pantelić, Gordana, "Evaluaton of dose rate data provided by non-governmental networks" in 30. симпозијум ДЗЗСЦГ : зборник радова (2019):297-302, https://hdl.handle.net/21.15107/rcub_vinar_11922 .