Nanoscale metal oxides as materials used for modification of carbon-based electrodes in electrochemical sensors
Conference object (Published version)
Metadata
Show full item recordAbstract
Nanostructured metal oxides used as modifiers of various carbon-based working electrodes serve as the basis for designing sensitive electrochemical sensors to detect desired analytes. The sensors we develop are distinguished by low detection limit (LOD), high analyte selectivity, sensitivity, and versatile real-world sample use case. In this work we present the design of two based on metal oxides as modifiers of carbon paste working electrode (CPE) and their applications in the electrochemical determination of levodopa and adrenaline. The physicochemical properties of designed materials were analyzed by complementary experimental technics (XRPD, TEM, SEM, EDS, electrochemical measurements) to determine their (micro)structural properties and correlate them with electroanalytical performance. Europium has been considered a significant lanthanide element with higher redox reaction behavior. We conducted a hydrothermal synthesis of Eu2O3@Cr2O3 and used them for CPE modification. The propos...ed Eu2O3@Cr2O3/CPE electrode was used to develop an analytical procedure quantifying L-Dopa in a wide micromolar linear range (1-100 µM), high sensitivity of 1.38 µA µM−1 cm−2 and a low detection limit (LOD = 0.72 µM). On the other side, we investigated the physicochemical properties of the gallium/bismuth mixed oxides and studied the influence of different Ga2O3:Bi2O3 ratios on the electrochemical detection of adrenaline. Square wave voltammetry was optimized, and the best electrode showed a wide linear working range of 7-100 μM, under optimized conditions. The LOD for the proposed sensor was calculated to be 1.9 μM, with a low limit of quantification (LOQ = 5.8 μM). The total performance of the sensors, particularly their performance on real-world samples and their potential for commercialization, had to be carefully evaluated during the sensor construction. Our team is devoted to developing highly selective electrochemical sensors based on nanomaterials to be potentially used as the basis for the fabrication of high-performance miniature devices with exceptional sensitivity to specific analytes, like adrenaline and L-Dopa, in this research.
Keywords:
Europium/chromium oxide / gallium/bismuth oxide / electrochemistry / levodopa / epinephrineSource:
MME SEE : 5th Metallurgical and Materials Engineering Congress of South-East Europe : book of abstracts; June 7-10, Trebinje, Bosnia and Herzegovina, 2023, 76-76Publisher:
- Association of Metallurgical Engineers of Serbia (AMES)
Collections
Institution/Community
VinčaTY - CONF AU - Ognjanović, Miloš AU - Dojčinović, Biljana AU - Antić, Bratislav AU - Stanković, Dalibor PY - 2023 UR - https://vinar.vin.bg.ac.rs/handle/123456789/11679 AB - Nanostructured metal oxides used as modifiers of various carbon-based working electrodes serve as the basis for designing sensitive electrochemical sensors to detect desired analytes. The sensors we develop are distinguished by low detection limit (LOD), high analyte selectivity, sensitivity, and versatile real-world sample use case. In this work we present the design of two based on metal oxides as modifiers of carbon paste working electrode (CPE) and their applications in the electrochemical determination of levodopa and adrenaline. The physicochemical properties of designed materials were analyzed by complementary experimental technics (XRPD, TEM, SEM, EDS, electrochemical measurements) to determine their (micro)structural properties and correlate them with electroanalytical performance. Europium has been considered a significant lanthanide element with higher redox reaction behavior. We conducted a hydrothermal synthesis of Eu2O3@Cr2O3 and used them for CPE modification. The proposed Eu2O3@Cr2O3/CPE electrode was used to develop an analytical procedure quantifying L-Dopa in a wide micromolar linear range (1-100 µM), high sensitivity of 1.38 µA µM−1 cm−2 and a low detection limit (LOD = 0.72 µM). On the other side, we investigated the physicochemical properties of the gallium/bismuth mixed oxides and studied the influence of different Ga2O3:Bi2O3 ratios on the electrochemical detection of adrenaline. Square wave voltammetry was optimized, and the best electrode showed a wide linear working range of 7-100 μM, under optimized conditions. The LOD for the proposed sensor was calculated to be 1.9 μM, with a low limit of quantification (LOQ = 5.8 μM). The total performance of the sensors, particularly their performance on real-world samples and their potential for commercialization, had to be carefully evaluated during the sensor construction. Our team is devoted to developing highly selective electrochemical sensors based on nanomaterials to be potentially used as the basis for the fabrication of high-performance miniature devices with exceptional sensitivity to specific analytes, like adrenaline and L-Dopa, in this research. PB - Association of Metallurgical Engineers of Serbia (AMES) C3 - MME SEE : 5th Metallurgical and Materials Engineering Congress of South-East Europe : book of abstracts; June 7-10, Trebinje, Bosnia and Herzegovina T1 - Nanoscale metal oxides as materials used for modification of carbon-based electrodes in electrochemical sensors SP - 76 EP - 76 UR - https://hdl.handle.net/21.15107/rcub_vinar_11679 ER -
@conference{ author = "Ognjanović, Miloš and Dojčinović, Biljana and Antić, Bratislav and Stanković, Dalibor", year = "2023", abstract = "Nanostructured metal oxides used as modifiers of various carbon-based working electrodes serve as the basis for designing sensitive electrochemical sensors to detect desired analytes. The sensors we develop are distinguished by low detection limit (LOD), high analyte selectivity, sensitivity, and versatile real-world sample use case. In this work we present the design of two based on metal oxides as modifiers of carbon paste working electrode (CPE) and their applications in the electrochemical determination of levodopa and adrenaline. The physicochemical properties of designed materials were analyzed by complementary experimental technics (XRPD, TEM, SEM, EDS, electrochemical measurements) to determine their (micro)structural properties and correlate them with electroanalytical performance. Europium has been considered a significant lanthanide element with higher redox reaction behavior. We conducted a hydrothermal synthesis of Eu2O3@Cr2O3 and used them for CPE modification. The proposed Eu2O3@Cr2O3/CPE electrode was used to develop an analytical procedure quantifying L-Dopa in a wide micromolar linear range (1-100 µM), high sensitivity of 1.38 µA µM−1 cm−2 and a low detection limit (LOD = 0.72 µM). On the other side, we investigated the physicochemical properties of the gallium/bismuth mixed oxides and studied the influence of different Ga2O3:Bi2O3 ratios on the electrochemical detection of adrenaline. Square wave voltammetry was optimized, and the best electrode showed a wide linear working range of 7-100 μM, under optimized conditions. The LOD for the proposed sensor was calculated to be 1.9 μM, with a low limit of quantification (LOQ = 5.8 μM). The total performance of the sensors, particularly their performance on real-world samples and their potential for commercialization, had to be carefully evaluated during the sensor construction. Our team is devoted to developing highly selective electrochemical sensors based on nanomaterials to be potentially used as the basis for the fabrication of high-performance miniature devices with exceptional sensitivity to specific analytes, like adrenaline and L-Dopa, in this research.", publisher = "Association of Metallurgical Engineers of Serbia (AMES)", journal = "MME SEE : 5th Metallurgical and Materials Engineering Congress of South-East Europe : book of abstracts; June 7-10, Trebinje, Bosnia and Herzegovina", title = "Nanoscale metal oxides as materials used for modification of carbon-based electrodes in electrochemical sensors", pages = "76-76", url = "https://hdl.handle.net/21.15107/rcub_vinar_11679" }
Ognjanović, M., Dojčinović, B., Antić, B.,& Stanković, D.. (2023). Nanoscale metal oxides as materials used for modification of carbon-based electrodes in electrochemical sensors. in MME SEE : 5th Metallurgical and Materials Engineering Congress of South-East Europe : book of abstracts; June 7-10, Trebinje, Bosnia and Herzegovina Association of Metallurgical Engineers of Serbia (AMES)., 76-76. https://hdl.handle.net/21.15107/rcub_vinar_11679
Ognjanović M, Dojčinović B, Antić B, Stanković D. Nanoscale metal oxides as materials used for modification of carbon-based electrodes in electrochemical sensors. in MME SEE : 5th Metallurgical and Materials Engineering Congress of South-East Europe : book of abstracts; June 7-10, Trebinje, Bosnia and Herzegovina. 2023;:76-76. https://hdl.handle.net/21.15107/rcub_vinar_11679 .
Ognjanović, Miloš, Dojčinović, Biljana, Antić, Bratislav, Stanković, Dalibor, "Nanoscale metal oxides as materials used for modification of carbon-based electrodes in electrochemical sensors" in MME SEE : 5th Metallurgical and Materials Engineering Congress of South-East Europe : book of abstracts; June 7-10, Trebinje, Bosnia and Herzegovina (2023):76-76, https://hdl.handle.net/21.15107/rcub_vinar_11679 .