Erratum: Systematic uncertainties in integrated luminosity measurement at CEPC (Journal of Instrumentation (2022) 17 (P09014) DOI: 10.1088/1748-0221/17/09/P09014)
2022
Preuzimanje 🢃
Autori
Smiljanić, IvanBožović-Jelisavčić, Ivanka
Kac̆arević, Goran
Vukašinović, Nataša
Vidaković, Ivana
Reković, Vladimir
Informativni prilog (Objavljena verzija)
Metapodaci
Prikaz svih podataka o dokumentuApstrakt
The very forward region is one of the most challenging regions to instrument at a future 𝑒 + 𝑒 − collider. At CEPC, machine-detector interface includes, among others, a calorimeter dedicated for precision measurement of the integrated luminosity at a per mill level or better. Here we review a feasibility of such precision, from the point of view of systematic effects arising from luminometer mechanical precision and positioning, beam-related requirements and physics background from two-photon processes. The impact of the beam energy spread and its uncertainty on the integrated luminosity precision is also discussed, as well as the achievable beam energy spread precision with the post-CDR CEPC beams
Izvor:
Journal of Instrumentation, 2022, 17, 12, E12001-Napomena:
- Link to the corrected article: https://vinar.vin.bg.ac.rs/handle/123456789/10567
Povezane informacije:
- Povezani sadržaj
https://vinar.vin.bg.ac.rs/handle/123456789/10566
Kolekcije
Institucija/grupa
VinčaTY - JOUR AU - Smiljanić, Ivan AU - Božović-Jelisavčić, Ivanka AU - Kac̆arević, Goran AU - Vukašinović, Nataša AU - Vidaković, Ivana AU - Reković, Vladimir PY - 2022 UR - https://vinar.vin.bg.ac.rs/handle/123456789/10567 AB - The very forward region is one of the most challenging regions to instrument at a future 𝑒 + 𝑒 − collider. At CEPC, machine-detector interface includes, among others, a calorimeter dedicated for precision measurement of the integrated luminosity at a per mill level or better. Here we review a feasibility of such precision, from the point of view of systematic effects arising from luminometer mechanical precision and positioning, beam-related requirements and physics background from two-photon processes. The impact of the beam energy spread and its uncertainty on the integrated luminosity precision is also discussed, as well as the achievable beam energy spread precision with the post-CDR CEPC beams T2 - Journal of Instrumentation T1 - Erratum: Systematic uncertainties in integrated luminosity measurement at CEPC (Journal of Instrumentation (2022) 17 (P09014) DOI: 10.1088/1748-0221/17/09/P09014) VL - 17 IS - 12 SP - E12001 DO - 10.1088/1748-0221/17/12/E12001 ER -
@article{ author = "Smiljanić, Ivan and Božović-Jelisavčić, Ivanka and Kac̆arević, Goran and Vukašinović, Nataša and Vidaković, Ivana and Reković, Vladimir", year = "2022", abstract = "The very forward region is one of the most challenging regions to instrument at a future 𝑒 + 𝑒 − collider. At CEPC, machine-detector interface includes, among others, a calorimeter dedicated for precision measurement of the integrated luminosity at a per mill level or better. Here we review a feasibility of such precision, from the point of view of systematic effects arising from luminometer mechanical precision and positioning, beam-related requirements and physics background from two-photon processes. The impact of the beam energy spread and its uncertainty on the integrated luminosity precision is also discussed, as well as the achievable beam energy spread precision with the post-CDR CEPC beams", journal = "Journal of Instrumentation", title = "Erratum: Systematic uncertainties in integrated luminosity measurement at CEPC (Journal of Instrumentation (2022) 17 (P09014) DOI: 10.1088/1748-0221/17/09/P09014)", volume = "17", number = "12", pages = "E12001", doi = "10.1088/1748-0221/17/12/E12001" }
Smiljanić, I., Božović-Jelisavčić, I., Kac̆arević, G., Vukašinović, N., Vidaković, I.,& Reković, V.. (2022). Erratum: Systematic uncertainties in integrated luminosity measurement at CEPC (Journal of Instrumentation (2022) 17 (P09014) DOI: 10.1088/1748-0221/17/09/P09014). in Journal of Instrumentation, 17(12), E12001. https://doi.org/10.1088/1748-0221/17/12/E12001
Smiljanić I, Božović-Jelisavčić I, Kac̆arević G, Vukašinović N, Vidaković I, Reković V. Erratum: Systematic uncertainties in integrated luminosity measurement at CEPC (Journal of Instrumentation (2022) 17 (P09014) DOI: 10.1088/1748-0221/17/09/P09014). in Journal of Instrumentation. 2022;17(12):E12001. doi:10.1088/1748-0221/17/12/E12001 .
Smiljanić, Ivan, Božović-Jelisavčić, Ivanka, Kac̆arević, Goran, Vukašinović, Nataša, Vidaković, Ivana, Reković, Vladimir, "Erratum: Systematic uncertainties in integrated luminosity measurement at CEPC (Journal of Instrumentation (2022) 17 (P09014) DOI: 10.1088/1748-0221/17/09/P09014)" in Journal of Instrumentation, 17, no. 12 (2022):E12001, https://doi.org/10.1088/1748-0221/17/12/E12001 . .