A compact fine-grained calorimeter for luminosity measurement at a linear collider
Апстракт
Based on a paper published in 2019 by the FCAL Collaboration, this talk is giving an update of the Collaboration's effort to design prototype of highly compact calorimeter to instrument the very forward region of a detector at future e+e- colliders. A luminometer prototype, based on sub-millimeter thick detector planes, is tested with an electron-beam of energy 1-5 GeV. The effective Molière radius of the prototype comprising eight detector planes was measured to be (8.1 ± 0.1 (stat) ± 0.3 (syst)) mm, and the result is well reproduced by the Monte Carlo simulation.
Извор:
Proceedings of the International Workshop on Future Linear Colliders, LCWS 2019, 2020Напомена:
- Talk presented at the International Workshop on Future Linear Colliders (LCWS2019), Sendai, Japan, 28 October-1 November, 2019. C19-10-28
Scopus: 2-s2.0-85086813928
Институција/група
VinčaTY - CONF AU - Božović-Jelisavčić, Ivanka PY - 2020 UR - https://vinar.vin.bg.ac.rs/handle/123456789/9044 UR - https://arxiv.org/abs/2002.03675 AB - Based on a paper published in 2019 by the FCAL Collaboration, this talk is giving an update of the Collaboration's effort to design prototype of highly compact calorimeter to instrument the very forward region of a detector at future e+e- colliders. A luminometer prototype, based on sub-millimeter thick detector planes, is tested with an electron-beam of energy 1-5 GeV. The effective Molière radius of the prototype comprising eight detector planes was measured to be (8.1 ± 0.1 (stat) ± 0.3 (syst)) mm, and the result is well reproduced by the Monte Carlo simulation. C3 - Proceedings of the International Workshop on Future Linear Colliders, LCWS 2019 T1 - A compact fine-grained calorimeter for luminosity measurement at a linear collider UR - https://hdl.handle.net/21.15107/rcub_vinar_9044 ER -
@conference{ author = "Božović-Jelisavčić, Ivanka", year = "2020", abstract = "Based on a paper published in 2019 by the FCAL Collaboration, this talk is giving an update of the Collaboration's effort to design prototype of highly compact calorimeter to instrument the very forward region of a detector at future e+e- colliders. A luminometer prototype, based on sub-millimeter thick detector planes, is tested with an electron-beam of energy 1-5 GeV. The effective Molière radius of the prototype comprising eight detector planes was measured to be (8.1 ± 0.1 (stat) ± 0.3 (syst)) mm, and the result is well reproduced by the Monte Carlo simulation.", journal = "Proceedings of the International Workshop on Future Linear Colliders, LCWS 2019", title = "A compact fine-grained calorimeter for luminosity measurement at a linear collider", url = "https://hdl.handle.net/21.15107/rcub_vinar_9044" }
Božović-Jelisavčić, I.. (2020). A compact fine-grained calorimeter for luminosity measurement at a linear collider. in Proceedings of the International Workshop on Future Linear Colliders, LCWS 2019. https://hdl.handle.net/21.15107/rcub_vinar_9044
Božović-Jelisavčić I. A compact fine-grained calorimeter for luminosity measurement at a linear collider. in Proceedings of the International Workshop on Future Linear Colliders, LCWS 2019. 2020;. https://hdl.handle.net/21.15107/rcub_vinar_9044 .
Božović-Jelisavčić, Ivanka, "A compact fine-grained calorimeter for luminosity measurement at a linear collider" in Proceedings of the International Workshop on Future Linear Colliders, LCWS 2019 (2020), https://hdl.handle.net/21.15107/rcub_vinar_9044 .