Optimal conditions for a ZnS(Ag) scintillation detector operation
Конференцијски прилог (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
The methods that use scintillation counting with ZnS(Ag) scintillation detector are widely used for gross alpha activity determination. Optimal counting conditions could be provided by properly setting of operating voltage and by this means, the long term stability could be achieved. The common criteria for the selection of optimal counting conditions for a ZnS(Ag) scintillation detector do not consider simultaneously operating voltage and discrimination level variation. In present method a relationship between voltage supply and discrimination level is derived for counting efficiency.
Кључне речи:
ZnS(Ag) scintillation detector / gross alpha activity / counting conditionsИзвор:
Balkan Physics Letters, 2004, Spec. issue, 217-221Напомена:
- Proceedings of the 4th international Balkan school on nuclear physics; Sept. 22-29, 2004; Bodrum (Turkey)
Колекције
Институција/група
VinčaTY - CONF AU - Đurašević, Mirjana M. AU - Kandić, Aleksandar AU - Novković, Dušan N. AU - Vukanac, Ivana PY - 2004 UR - https://vinar.vin.bg.ac.rs/handle/123456789/8651 AB - The methods that use scintillation counting with ZnS(Ag) scintillation detector are widely used for gross alpha activity determination. Optimal counting conditions could be provided by properly setting of operating voltage and by this means, the long term stability could be achieved. The common criteria for the selection of optimal counting conditions for a ZnS(Ag) scintillation detector do not consider simultaneously operating voltage and discrimination level variation. In present method a relationship between voltage supply and discrimination level is derived for counting efficiency. C3 - Balkan Physics Letters T1 - Optimal conditions for a ZnS(Ag) scintillation detector operation IS - Spec. issue SP - 217 EP - 221 UR - https://hdl.handle.net/21.15107/rcub_vinar_8651 ER -
@conference{ author = "Đurašević, Mirjana M. and Kandić, Aleksandar and Novković, Dušan N. and Vukanac, Ivana", year = "2004", abstract = "The methods that use scintillation counting with ZnS(Ag) scintillation detector are widely used for gross alpha activity determination. Optimal counting conditions could be provided by properly setting of operating voltage and by this means, the long term stability could be achieved. The common criteria for the selection of optimal counting conditions for a ZnS(Ag) scintillation detector do not consider simultaneously operating voltage and discrimination level variation. In present method a relationship between voltage supply and discrimination level is derived for counting efficiency.", journal = "Balkan Physics Letters", title = "Optimal conditions for a ZnS(Ag) scintillation detector operation", number = "Spec. issue", pages = "217-221", url = "https://hdl.handle.net/21.15107/rcub_vinar_8651" }
Đurašević, M. M., Kandić, A., Novković, D. N.,& Vukanac, I.. (2004). Optimal conditions for a ZnS(Ag) scintillation detector operation. in Balkan Physics Letters(Spec. issue), 217-221. https://hdl.handle.net/21.15107/rcub_vinar_8651
Đurašević MM, Kandić A, Novković DN, Vukanac I. Optimal conditions for a ZnS(Ag) scintillation detector operation. in Balkan Physics Letters. 2004;(Spec. issue):217-221. https://hdl.handle.net/21.15107/rcub_vinar_8651 .
Đurašević, Mirjana M., Kandić, Aleksandar, Novković, Dušan N., Vukanac, Ivana, "Optimal conditions for a ZnS(Ag) scintillation detector operation" in Balkan Physics Letters, no. Spec. issue (2004):217-221, https://hdl.handle.net/21.15107/rcub_vinar_8651 .