Приказ основних података о документу
Accuracy in determining absorbed irradiation dose at different temperature measurements using ethanol chlorobenzene - oscillotitrator system
dc.creator | Vujčić, Ivica | |
dc.creator | Mašić, Slobodan | |
dc.creator | Spasevska, Hristina | |
dc.creator | Dramićanin, Miroslav | |
dc.date.accessioned | 2019-06-04T09:29:14Z | |
dc.date.available | 2019-06-04T09:29:14Z | |
dc.date.issued | 2018 | |
dc.identifier.issn | 1451-3994 | |
dc.identifier.issn | 1452-8185 | |
dc.identifier.uri | http://www.doiserbia.nb.rs/Article.aspx?ID=1451-39941800004V | |
dc.identifier.uri | https://vinar.vin.bg.ac.rs/handle/123456789/8121 | |
dc.description.abstract | Elhanol-chlorobenzene/oscillolilralor dosimetry system is widely used in controlling the irradiation process in gamma facilities. The elhanol-chlorobenzene dosimetry system provides a reliable means of measuring absorbed dose. It is based on a process of radiolytic formation of hydrochloric acid in aqueous elhanolic solutions of chlorobenzene by ionizing radiation. The irradiation temperature dependence of dosimeter response is a complex function of dose and temperature for each concentration of chlorobenzene. At different temperature the mobility of conducting species from hydrochloric acid is changed leading to dilTerenl oscillolilralor deflections during high-frequency conduclomelric readout. In this paper, we examined the influence of temperature on the calculation of the radiation dose. We showed that the temperature significantly influenced the measurement results, and that the calibration curve has to be formed at the irradiation temperature in order to obtain precise values of the absorbed dose. © 2018; Vinca Inst Nuclear Sci. All rights reserved. | en |
dc.language.iso | en | |
dc.relation | info:eu-repo/grantAgreement/MESTD/Integrated and Interdisciplinary Research (IIR or III)/45020/RS// | |
dc.rights | openAccess | |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.source | Nuclear Technology and Radiation Protection | |
dc.subject | ethanol-chlorobenzene | en |
dc.subject | oscillotitrator | en |
dc.subject | dosimetry | en |
dc.title | Accuracy in determining absorbed irradiation dose at different temperature measurements using ethanol chlorobenzene - oscillotitrator system | en |
dc.type | article | en |
dc.rights.license | BY-NC-ND | |
dcterms.abstract | Вујчић, Ивица; Машић, Слободан; Драмићанин, Мирослав; Спасевска, Христина; | |
dc.citation.volume | 33 | |
dc.citation.issue | 4 | |
dc.citation.spage | 363 | |
dc.citation.epage | 368 | |
dc.identifier.wos | 000466815000006 | |
dc.identifier.doi | 10.2298/NTRP180316004V | |
dc.citation.rank | M23 | |
dc.type.version | publishedVersion | |
dc.identifier.scopus | 2-s2.0-85063476249 | |
dc.identifier.fulltext | https://vinar.vin.bg.ac.rs//bitstream/id/11254/1451-39941800004V.pdf |
Документи
Овај документ се појављује у следећим колекцијама
-
Radovi istraživača
Researchers' publications