Приказ основних података о документу

dc.creatorCinkova, Kristina
dc.creatorKianičkova, Kristina
dc.creatorStanković, Dalibor M.
dc.creatorVojs, Marian
dc.creatorMarton, Marian
dc.creatorŠvorc, Lubomir
dc.date.accessioned2018-06-20T07:30:56Z
dc.date.available2018-06-20T07:30:56Z
dc.date.issued2018
dc.identifier.issn1759-9660
dc.identifier.urihttps://vinar.vin.bg.ac.rs/handle/123456789/7662
dc.description.abstractIn this work, the electrochemical oxidation and subsequent determination of uric acid was investigated using boron-doped diamond electrodes with various B/C ratios (0-2000 ppm). The cyclic voltammetric study showed one irreversible oxidation peak at +(1.1-1.25) V (vs. Ag/AgCl/3 M KCl) in the presence of Britton-Robinson buffer (pH 2.25) depending on the boron content. Employing differential pulse voltammetry using the 2000 ppm boron-doped diamond electrode the acquired analytical parameters were as follows: a limit of detection of 7.7 M, a limit of quantification of 26 M and intra-day repeatability (relative standard deviation of 2.9% for n = 15). After performing an interference study, the method was applied to the determination of uric acid in biological samples (human urine). The uric acid concentrations determined in the urine samples were compared with the reference values stated in the literature. The proposed methodology using boron-doped diamond electrodes could find applications in uric acid sensing within clinical, pharmaceutical and environmental analysis.en
dc.relationinfo:eu-repo/grantAgreement/MESTD/Basic Research (BR or ON)/172030/RS//
dc.relationinfo:eu-repo/grantAgreement/EC/FP7/621375/EU//
dc.relationGrant Agency of the Slovak Republic [1/0489/16]
dc.relationGrant Agency of the Slovak Republic [1/0887/16]
dc.relationGrant Agency of the Slovak Republic [1/0558/17]
dc.relationSlovak Research and Development Agency [APVV-16-0124]
dc.relationGrant scheme for Support of Excellent Teams of Young Researchers
dc.rightsrestrictedAccess
dc.sourceAnalytical Methods
dc.subject.otheranalytical parametersen
dc.subject.otherboron doped diamond electrodesen
dc.subject.otherBritton-Robinson bufferen
dc.subject.otherdifferential pulse voltammetryen
dc.subject.otherenvironmental analysisen
dc.subject.otherirreversible oxydationen
dc.subject.otherelectrochemical electrodesen
dc.titleThe doping level of boron-doped diamond electrodes affects the voltammetric sensing of uric aciden
dc.typearticleen
dc.rights.licenseARR
dcterms.abstractСтанковић, Далибор М.; Цинкова, Кристина; Кианичкова, Кристина; Војс, Мариан; Мартон, Мариан; Шворц, Лубомир;
dc.rights.holder© The Royal Society of Chemistry, 2018
dc.citation.volume10
dc.citation.issue9
dc.citation.spage991
dc.citation.epage996
dc.identifier.wos000426696100009
dc.identifier.doi10.1039/C7AY02720F
dc.citation.rankM22
dc.type.versionpublishedVersion
dc.identifier.scopus2-s2.0-85042884267


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу