Boron-doped diamond electrode - A prestigious unmodified carbon electrode for simple and fast determination of bentazone in river water samples
Samo za registrovane korisnike
2018
Autori
Jevtić, SonjaStefanović, Anđela
Stanković, Dalibor M.
Pergal, Marija V.
Ivanović, Aleksandra T.
Jokić, Anja
Petković, Branka B.
Članak u časopisu (Objavljena verzija)
,
© 2017 Elsevier B.V.
Metapodaci
Prikaz svih podataka o dokumentuApstrakt
Bentazone (BZ) is selective contact-past herbicide with suspected reproductive toxicity potential for human due to possible contamination of ground and surface waters. This work presents simple, rapid, sensitive and accurate determination of bentazone at unmodified boron-doped diamond electrode, using differential pulse voltammetry in Britton-Robinson buffer (pH 4, oxidation peak at 1.0 V). Under optimized DPV conditions linear calibration curve was obtained for range of 2 to 100 mu M, with a detection limit of 0.5 mu M. The effect of possible interfering agents is negligible, confirming good selectivity of the method. The method was successfully applied to determination of bentazone in spiked river water samples. This electrochemical determination of bentazone represents a favorable alternative to other used time-consuming and expensive analytical techniques and procedures.
Ključne reči:
Bentazone determination / Electrochemical method / Voltanunetry / River water samplesIzvor:
Diamond and Related Materials, 2018, 81, 133-137Finansiranje / projekti:
- Višeskalno strukturiranje polimernih nanokompozita i funkcionalnih materijala primenom različitih prekursora (RS-MESTD-Integrated and Interdisciplinary Research (IIR or III)-45022)
- Primena unapređenih oksidacionih procesa i nanostrukturisanih oksidnih materijala za uklanjanje zagađivača iz životne sredine, razvoj i optimizacija instrumentalnih tehnika za praćenje efikasnosti (RS-MESTD-Basic Research (BR or ON)-172030)
- Strengthening of the MagBioVin Research and Innovation Team for Development of Novel Approaches for Tumour Therapy based on Nanostructured Materials (EU-FP7-621375)
DOI: 10.1016/j.diamond.2017.12.009
ISSN: 0925-9635
WoS: 000424310600018
Scopus: 2-s2.0-85037548233
Kolekcije
Institucija/grupa
VinčaTY - JOUR AU - Jevtić, Sonja AU - Stefanović, Anđela AU - Stanković, Dalibor M. AU - Pergal, Marija V. AU - Ivanović, Aleksandra T. AU - Jokić, Anja AU - Petković, Branka B. PY - 2018 UR - https://vinar.vin.bg.ac.rs/handle/123456789/7589 AB - Bentazone (BZ) is selective contact-past herbicide with suspected reproductive toxicity potential for human due to possible contamination of ground and surface waters. This work presents simple, rapid, sensitive and accurate determination of bentazone at unmodified boron-doped diamond electrode, using differential pulse voltammetry in Britton-Robinson buffer (pH 4, oxidation peak at 1.0 V). Under optimized DPV conditions linear calibration curve was obtained for range of 2 to 100 mu M, with a detection limit of 0.5 mu M. The effect of possible interfering agents is negligible, confirming good selectivity of the method. The method was successfully applied to determination of bentazone in spiked river water samples. This electrochemical determination of bentazone represents a favorable alternative to other used time-consuming and expensive analytical techniques and procedures. T2 - Diamond and Related Materials T1 - Boron-doped diamond electrode - A prestigious unmodified carbon electrode for simple and fast determination of bentazone in river water samples VL - 81 SP - 133 EP - 137 DO - 10.1016/j.diamond.2017.12.009 ER -
@article{ author = "Jevtić, Sonja and Stefanović, Anđela and Stanković, Dalibor M. and Pergal, Marija V. and Ivanović, Aleksandra T. and Jokić, Anja and Petković, Branka B.", year = "2018", abstract = "Bentazone (BZ) is selective contact-past herbicide with suspected reproductive toxicity potential for human due to possible contamination of ground and surface waters. This work presents simple, rapid, sensitive and accurate determination of bentazone at unmodified boron-doped diamond electrode, using differential pulse voltammetry in Britton-Robinson buffer (pH 4, oxidation peak at 1.0 V). Under optimized DPV conditions linear calibration curve was obtained for range of 2 to 100 mu M, with a detection limit of 0.5 mu M. The effect of possible interfering agents is negligible, confirming good selectivity of the method. The method was successfully applied to determination of bentazone in spiked river water samples. This electrochemical determination of bentazone represents a favorable alternative to other used time-consuming and expensive analytical techniques and procedures.", journal = "Diamond and Related Materials", title = "Boron-doped diamond electrode - A prestigious unmodified carbon electrode for simple and fast determination of bentazone in river water samples", volume = "81", pages = "133-137", doi = "10.1016/j.diamond.2017.12.009" }
Jevtić, S., Stefanović, A., Stanković, D. M., Pergal, M. V., Ivanović, A. T., Jokić, A.,& Petković, B. B.. (2018). Boron-doped diamond electrode - A prestigious unmodified carbon electrode for simple and fast determination of bentazone in river water samples. in Diamond and Related Materials, 81, 133-137. https://doi.org/10.1016/j.diamond.2017.12.009
Jevtić S, Stefanović A, Stanković DM, Pergal MV, Ivanović AT, Jokić A, Petković BB. Boron-doped diamond electrode - A prestigious unmodified carbon electrode for simple and fast determination of bentazone in river water samples. in Diamond and Related Materials. 2018;81:133-137. doi:10.1016/j.diamond.2017.12.009 .
Jevtić, Sonja, Stefanović, Anđela, Stanković, Dalibor M., Pergal, Marija V., Ivanović, Aleksandra T., Jokić, Anja, Petković, Branka B., "Boron-doped diamond electrode - A prestigious unmodified carbon electrode for simple and fast determination of bentazone in river water samples" in Diamond and Related Materials, 81 (2018):133-137, https://doi.org/10.1016/j.diamond.2017.12.009 . .