Ad-hoc intercomparison of four different radon exhalation measurement methods
Само за регистроване кориснике
2018
Аутори
Awhida, AhmedUjić, Predrag
Pantelić, Gordana K.
Kolarž, Predrag M.
Čeliković, Igor T.
Živanović, Miloš Z.
Janićijević, Aco
Lončar, Boris B.
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
It is indicated that the exposure to radon originating from the building materials is not negligible and the radon exhalation measurement should get more attention in the future. The experience with four different methods of the exhalation measurement, established in our laboratory for the purpose of the intercomparison is reported. Additionally, a comparison of advantages and disadvantages of used methods is discussed.
Извор:
Radiation Protection Dosimetry, 2018, 178, 138-142Финансирање / пројекти:
- Нуклеарна физика, методе и примена (RS-171018)
- Физички и функционални ефекти интеракције зрачења са електротехничким и биолошким системима (RS-171007)
- Нове технологије за мониторинг и заштиту животног окружења од штетних хемијских супстанци и радијационог оптерећења (RS-43009)
DOI: 10.1093/rpd/ncx096
ISSN: 0144-8420
PubMed: 28985374
WoS: 000425534500002
Scopus: 2-s2.0-85044592023
Колекције
Институција/група
VinčaTY - JOUR AU - Awhida, Ahmed AU - Ujić, Predrag AU - Pantelić, Gordana K. AU - Kolarž, Predrag M. AU - Čeliković, Igor T. AU - Živanović, Miloš Z. AU - Janićijević, Aco AU - Lončar, Boris B. PY - 2018 UR - https://vinar.vin.bg.ac.rs/handle/123456789/7588 AB - It is indicated that the exposure to radon originating from the building materials is not negligible and the radon exhalation measurement should get more attention in the future. The experience with four different methods of the exhalation measurement, established in our laboratory for the purpose of the intercomparison is reported. Additionally, a comparison of advantages and disadvantages of used methods is discussed. T2 - Radiation Protection Dosimetry T1 - Ad-hoc intercomparison of four different radon exhalation measurement methods VL - 178 SP - 138 EP - 142 DO - 10.1093/rpd/ncx096 ER -
@article{ author = "Awhida, Ahmed and Ujić, Predrag and Pantelić, Gordana K. and Kolarž, Predrag M. and Čeliković, Igor T. and Živanović, Miloš Z. and Janićijević, Aco and Lončar, Boris B.", year = "2018", abstract = "It is indicated that the exposure to radon originating from the building materials is not negligible and the radon exhalation measurement should get more attention in the future. The experience with four different methods of the exhalation measurement, established in our laboratory for the purpose of the intercomparison is reported. Additionally, a comparison of advantages and disadvantages of used methods is discussed.", journal = "Radiation Protection Dosimetry", title = "Ad-hoc intercomparison of four different radon exhalation measurement methods", volume = "178", pages = "138-142", doi = "10.1093/rpd/ncx096" }
Awhida, A., Ujić, P., Pantelić, G. K., Kolarž, P. M., Čeliković, I. T., Živanović, M. Z., Janićijević, A.,& Lončar, B. B.. (2018). Ad-hoc intercomparison of four different radon exhalation measurement methods. in Radiation Protection Dosimetry, 178, 138-142. https://doi.org/10.1093/rpd/ncx096
Awhida A, Ujić P, Pantelić GK, Kolarž PM, Čeliković IT, Živanović MZ, Janićijević A, Lončar BB. Ad-hoc intercomparison of four different radon exhalation measurement methods. in Radiation Protection Dosimetry. 2018;178:138-142. doi:10.1093/rpd/ncx096 .
Awhida, Ahmed, Ujić, Predrag, Pantelić, Gordana K., Kolarž, Predrag M., Čeliković, Igor T., Živanović, Miloš Z., Janićijević, Aco, Lončar, Boris B., "Ad-hoc intercomparison of four different radon exhalation measurement methods" in Radiation Protection Dosimetry, 178 (2018):138-142, https://doi.org/10.1093/rpd/ncx096 . .