Performance of Radiation Survey Meters in X- and Gamma-Radiation Fields
Нема приказа
Аутори
Ćeklić, SandraAranđić, Danijela
Živanović, Miloš Z.
Ciraj-Bjelac, Olivera
Lazarević, Đorđe R.
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
The aim of this work was to investigate the different types of radiation detectors commonly used for radiation protection purposes as survey meters. The study was performed on survey meters that use different detectors as ionisation chamber, Geiger Mueller (GM) counter and scintillation detector. For each survey meter, energy dependence and angular response in X-and gamma-radiation fields was tested. The following commercially available survey meters were investigated: ionisation chambers Victoreen 451P, Babyline 31 and VA-J-15A, Geiger counter MRK-M87, 6150 AD6 and FAG FH 40F2 and scintillation counter 6150 ADB. As a source of gamma radiation, Cs-137 and Co-60 were used whereas X-ray radiation fields were generated using an X-ray unit. The radiation characteristics of the survey meters were mostly in compliance with references estimated by standard IEC 1017-2. However, some of them showed larger deviation at lower energies. GM counters exhibit strong energy dependence for low-energy p...hotons.
Извор:
Radiation Protection Dosimetry, 2014, 162, 1-2, 139-143Финансирање / пројекти:
- Нови приступ проблемима заснивања квантне механике са аспекта примене у квантним технологијама и интерпретацијама сигнала различитог порекла (RS-MESTD-Basic Research (BR or ON)-171028)
Напомена:
- 2nd International Conference on Radiation and Dosimetry in Various Fields of Research RAD and The 2nd East European Radon Symposium (SEERAS), May 27-30, 2014, Nis, Serbia
DOI: 10.1093/rpd/ncu246
ISSN: 0144-8420; 1742-3406
PubMed: 25063785
WoS: 000347733500031
Scopus: 2-s2.0-84922430829
Колекције
Институција/група
VinčaTY - JOUR AU - Ćeklić, Sandra AU - Aranđić, Danijela AU - Živanović, Miloš Z. AU - Ciraj-Bjelac, Olivera AU - Lazarević, Đorđe R. PY - 2014 UR - https://vinar.vin.bg.ac.rs/handle/123456789/7049 AB - The aim of this work was to investigate the different types of radiation detectors commonly used for radiation protection purposes as survey meters. The study was performed on survey meters that use different detectors as ionisation chamber, Geiger Mueller (GM) counter and scintillation detector. For each survey meter, energy dependence and angular response in X-and gamma-radiation fields was tested. The following commercially available survey meters were investigated: ionisation chambers Victoreen 451P, Babyline 31 and VA-J-15A, Geiger counter MRK-M87, 6150 AD6 and FAG FH 40F2 and scintillation counter 6150 ADB. As a source of gamma radiation, Cs-137 and Co-60 were used whereas X-ray radiation fields were generated using an X-ray unit. The radiation characteristics of the survey meters were mostly in compliance with references estimated by standard IEC 1017-2. However, some of them showed larger deviation at lower energies. GM counters exhibit strong energy dependence for low-energy photons. T2 - Radiation Protection Dosimetry T1 - Performance of Radiation Survey Meters in X- and Gamma-Radiation Fields VL - 162 IS - 1-2 SP - 139 EP - 143 DO - 10.1093/rpd/ncu246 ER -
@article{ author = "Ćeklić, Sandra and Aranđić, Danijela and Živanović, Miloš Z. and Ciraj-Bjelac, Olivera and Lazarević, Đorđe R.", year = "2014", abstract = "The aim of this work was to investigate the different types of radiation detectors commonly used for radiation protection purposes as survey meters. The study was performed on survey meters that use different detectors as ionisation chamber, Geiger Mueller (GM) counter and scintillation detector. For each survey meter, energy dependence and angular response in X-and gamma-radiation fields was tested. The following commercially available survey meters were investigated: ionisation chambers Victoreen 451P, Babyline 31 and VA-J-15A, Geiger counter MRK-M87, 6150 AD6 and FAG FH 40F2 and scintillation counter 6150 ADB. As a source of gamma radiation, Cs-137 and Co-60 were used whereas X-ray radiation fields were generated using an X-ray unit. The radiation characteristics of the survey meters were mostly in compliance with references estimated by standard IEC 1017-2. However, some of them showed larger deviation at lower energies. GM counters exhibit strong energy dependence for low-energy photons.", journal = "Radiation Protection Dosimetry", title = "Performance of Radiation Survey Meters in X- and Gamma-Radiation Fields", volume = "162", number = "1-2", pages = "139-143", doi = "10.1093/rpd/ncu246" }
Ćeklić, S., Aranđić, D., Živanović, M. Z., Ciraj-Bjelac, O.,& Lazarević, Đ. R.. (2014). Performance of Radiation Survey Meters in X- and Gamma-Radiation Fields. in Radiation Protection Dosimetry, 162(1-2), 139-143. https://doi.org/10.1093/rpd/ncu246
Ćeklić S, Aranđić D, Živanović MZ, Ciraj-Bjelac O, Lazarević ĐR. Performance of Radiation Survey Meters in X- and Gamma-Radiation Fields. in Radiation Protection Dosimetry. 2014;162(1-2):139-143. doi:10.1093/rpd/ncu246 .
Ćeklić, Sandra, Aranđić, Danijela, Živanović, Miloš Z., Ciraj-Bjelac, Olivera, Lazarević, Đorđe R., "Performance of Radiation Survey Meters in X- and Gamma-Radiation Fields" in Radiation Protection Dosimetry, 162, no. 1-2 (2014):139-143, https://doi.org/10.1093/rpd/ncu246 . .