dc.description.abstractAccurate monitoring of indoor mass concentrations of particulate matter is very important for health risk assessment as people in developed countries spend approximately 90% of their time indoors. The direct reading, aerosol monitoring device, Turnkey, OSIRIS Particle Monitor (Model 2315) and the European reference low volume sampler, LVS3 (Sven/Leckel LVS3) with size-selective inlets for PM10 and PM2.5 fractions were used to assess the comparability of available optical and gravimetric methods for particulate matter characterization in indoor air. Simultaneous 24-hour samples were collected in an indoor environment for 60 sampling periods in the town of Bor, Serbia. The 24-hour mean PM10 levels from the OSIRIS monitor were well correlated with the LVS3 levels (R-2=0.87) and did not show statistically significant bias. The 24-hour mean PM2.5 levels from the OSIRIS monitor were moderately correlated with the LVS3 levels (R-2=0.71), but show statistically significant bias. The results suggest that the OSIRIS monitor provides sufficiently accurate measurements for PM10. The OSIRIS monitor under-estimated the indoor PM10 concentrations by approximately 12%, relative to the reference LVS3 sampler. The accuracy of PM10 measurements could be further improved through empirical adjustment. For the fine fraction of particulate matter, PM2.5, it was found that the OSIRIS monitor underestimated indoor concentrations by approximately 63%, relative to the reference LVS3 sampler. This could lead to exposure misclassification in health effects studies relying on PM2.5 measurements collected with this instrument in indoor environments. (C) 2012 Elsevier Ltd. All rights reserved.en
dc.relationinfo:eu-repo/grantAgreement/MESTD/Integrated and Interdisciplinary Research (IIR or III)/42008/RS//
dc.rightsrestrictedAccessen
dc.sourceAtmospheric Environmenten
dc.subjectParticulate matteren
dc.subjectOptical monitoren
dc.subjectIndoor air pollutionen
dc.subjectAerosol monitoringen
dc.subjectExposure assessmenten
dc.titleComparative assessment of a real-time particle monitor against the reference gravimetric method for PM10 and PM2.5 in indoor airen
dc.typearticleen
dc.rights.licenseARR
dcterms.abstractЈовашевић-Стојановић Милена; Петровиц, Јелена; Милосевиц, Новица; Тасиц, Виса; Вардоулакис, Сотирис; Ковацевиц, Рената;
dc.citation.volume54
dc.citation.spage358
dc.citation.epage364
dc.identifier.wos000306200600043
dc.identifier.doi10.1016/j.atmosenv.2012.02.030
dc.citation.rankM21
dc.type.versionpublishedVersion
dc.identifier.scopus2-s2.0-84860637386


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу