Приказ основних података о документу
Radiation protection of patients in diagnostic radiology: Status of practice in five Eastern-European countries, based on IAEA project
dc.creator | Ciraj-Bjelac, Olivera | |
dc.creator | Beganovic, Adnan | |
dc.creator | Faj, Dario | |
dc.creator | Gershan, Vesna | |
dc.creator | Ivanović, Sonja | |
dc.creator | Videnovic, Ivan R. | |
dc.creator | Rehani, Madan M. | |
dc.date.accessioned | 2018-03-01T21:56:44Z | |
dc.date.available | 2018-03-01T21:56:44Z | |
dc.date.issued | 2011 | |
dc.identifier.issn | 0720-048X | |
dc.identifier.uri | https://vinar.vin.bg.ac.rs/handle/123456789/4462 | |
dc.description.abstract | The purpose of this work was to investigate status of imaging technology and practice in five countries in Eastern-European region and evaluate the impact of IAEA projects on radiation protection of patients. Information collected using standardized IAEA protocol included status of technology, practices and patient dose levels in interventional procedure, radiography, mammography and computed tomography (CT). In spite of increased number of digital units, single phase generators or units older than 30 year are still in use. Examples of obsolete practice such as using fluoroscopy for positioning, photofluorography, chest fluoroscopy and soft-beam technique for chest radiography are also in use. Modern multi-slice CT or digital mammography units are available; however, there is lack of adequate radiation protection and medical physics support in hospitals. Information on patient doses in interventional procedures, conventional radiography, mammography and CT was collected to have baseline data and corrective measures were proposed with appropriate follow up actions taken. (C) 2011 Elsevier Ireland Ltd. All rights reserved. | en |
dc.rights | restrictedAccess | en |
dc.source | European Journal of Radiology | en |
dc.subject | Radiation safety in interventional procedure | en |
dc.subject | Radiation safety radiography | en |
dc.subject | Radiation safety mammography | en |
dc.subject | Radiation safety computed tomography | en |
dc.subject | Radiation protection | en |
dc.subject | Radiation dose management | en |
dc.title | Radiation protection of patients in diagnostic radiology: Status of practice in five Eastern-European countries, based on IAEA project | en |
dc.type | article | en |
dcterms.abstract | Бегановиц, Aднан; Рехани, Мадан М.; Цирај-Бјелац Оливера; Виденовиц, Иван Р.; Ивановиц, Соња; Герсхан, Весна; Фај, Дарио; | |
dc.citation.volume | 79 | |
dc.citation.issue | 2 | |
dc.citation.spage | E70 | |
dc.citation.epage | E73 | |
dc.identifier.wos | 000294292700014 | |
dc.identifier.doi | 10.1016/j.ejrad.2011.03.075 | |
dc.citation.rank | M22 | |
dc.identifier.pmid | 21507590 | |
dc.identifier.scopus | 2-s2.0-80052142617 |
Документи
Датотеке | Величина | Формат | Преглед |
---|---|---|---|
Уз овај запис нема датотека. |