Приказ основних података о документу

dc.creatorŠećerov, Bojana Lj.
dc.creatorDakovic, Marko
dc.creatorBorojević, Nenad
dc.creatorBačić, Goran
dc.date.accessioned2018-03-01T21:38:31Z
dc.date.available2018-03-01T21:38:31Z
dc.date.issued2011
dc.identifier.issn0168-9002
dc.identifier.urihttps://vinar.vin.bg.ac.rs/handle/123456789/4250
dc.description.abstractVarious forms of Gafchromic films that are increasingly used for dosimetry in radiotherapy offer the prospect of reproducible and accurate high-resolution two-dimensional dose measurements, but there are many unresolved issues regarding the optimal choice of densitometric procedure used for the films optical density (OD) readout. There are conflicting requirements for scanners (sensitivity, availability, price) and commercial document scanners appears to be a reasonable option, hence we analyzed the measured sublinear dose response of these scanners. Using measured film absorption spectra we were able to make quantitative distinction between various factors affecting the sublinearity and to demonstrate that the dose response curve can be predicted for any selected light source used for scanning. We also used the commercial narrow bandpass filters in conjunction with document scanners to investigate whether such an inexpensive option can improve their sensitivity, but results were not encouraging. Finally, we analyzed the suitability of proposed fitting equations for the calibration of the dose response and found that their reliability largely depends on the dose range used for the calibration. (C) 2011 Elsevier B.V. All rights reserved.en
dc.relationMinistry of Sciences and Environmental Protection, Republic of Serbia [143016]
dc.rightsrestrictedAccessen
dc.sourceNuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipmenten
dc.subjectRadochromic filmsen
dc.subjectDosimetryen
dc.subjectDose response curve analysisen
dc.subjectSensitivityen
dc.titleDosimetry using HS GafChromic films the influence of readout light on sensitivity of dosimetryen
dc.typearticleen
dcterms.abstractШећеров Бојана Љ; Даковиц, Марко; Боројевиц, Ненад; Бациц, Горан;
dc.citation.volume633
dc.citation.issue1
dc.citation.spage66
dc.citation.epage71
dc.identifier.wos000288572700010
dc.identifier.doi10.1016/j.nima.2010.12.234
dc.citation.rankM22
dc.identifier.scopus2-s2.0-79951814470