Performance of the CMS cathode strip chambers with cosmic rays
2010
Аутори
Chatrchyan, S.Adžić, Petar
Đorđević, Miloš
Jovanović, Dragana J.
Krpić, D.
Maletić, Dimitrije
Puzović, Jovan M.
Smiljković, Nikola
Milenović, Predrag
(ukupan broj autora: 2423)
Чланак у часопису
Метаподаци
Приказ свих података о документуАпстракт
The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 mu m to 243 mu m. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns.
Кључне речи:
Large detector systems for particle and astroparticle physics / Particle tracking detectors (Gaseous detectors)Извор:
Journal of Instrumentation, 2010, 5Финансирање / пројекти:
- FMSR (Austria), FNRS (Belgium), CNPq (Brazil), CAPES (Brazil), FAPERJ (Brazil), FAPESP (Brazil), MES (Bulgaria), CERN, CAS (China), MoST (China), NSFC (China), COLCIENCIAS (Colombia), MSES (Croatia), RPF (Cyprus), Academy of Sciences, NICPB (Estonia), Academy of Finland, ME (Finland), HIP (Finland), CEA (France), CNRS/IN2P3 (France), BMBF, Germany, DFG (Germany), HGF (Germany), GSRT (Greece), OTKA (Hungary), NKTH (Hungary), DAE (India), DST (India), IPM (Iran), SFI (Ireland), INFN (Italy), NRF (Korea), LAS (Lithuania), CINVESTAV (Mexico), CONACYT (Mexico), SEP (Mexico), UASLP-FAI (Mexico), PAEC (Pakistan), SCSR (Poland), FCT (Portugal), JINR (Armenia), JINR (Belarus), JINR (Georgia), JINR (Ukraine), JINR (Uzbekistan), MST (Russia), MAE (Russia), MSTDS (Serbia), MICINN (Spain), CPAN (Spain), Swiss Funding Agencies (Switzerland), NSC (Taipei), TUBITAK (Turkey), TAEK (Turkey), STFC (United Kingdom), DOE (USA), NSF (USA), European Union, Leventis Foundation, A.P. Sloan Foundation, Alexander von Humboldt Foundation, FWO (Belgium)
DOI: 10.1088/1748-0221/5/03/T03018
ISSN: 1748-0221
WoS: 000280524100015
Scopus: 2-s2.0-79953292228
Колекције
Институција/група
VinčaTY - JOUR AU - Chatrchyan, S. AU - Adžić, Petar AU - Đorđević, Miloš AU - Jovanović, Dragana J. AU - Krpić, D. AU - Maletić, Dimitrije AU - Puzović, Jovan M. AU - Smiljković, Nikola AU - Milenović, Predrag PY - 2010 UR - https://vinar.vin.bg.ac.rs/handle/123456789/4066 AB - The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 mu m to 243 mu m. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns. T2 - Journal of Instrumentation T1 - Performance of the CMS cathode strip chambers with cosmic rays VL - 5 DO - 10.1088/1748-0221/5/03/T03018 ER -
@article{ author = "Chatrchyan, S. and Adžić, Petar and Đorđević, Miloš and Jovanović, Dragana J. and Krpić, D. and Maletić, Dimitrije and Puzović, Jovan M. and Smiljković, Nikola and Milenović, Predrag", year = "2010", abstract = "The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 mu m to 243 mu m. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns.", journal = "Journal of Instrumentation", title = "Performance of the CMS cathode strip chambers with cosmic rays", volume = "5", doi = "10.1088/1748-0221/5/03/T03018" }
Chatrchyan, S., Adžić, P., Đorđević, M., Jovanović, D. J., Krpić, D., Maletić, D., Puzović, J. M., Smiljković, N.,& Milenović, P.. (2010). Performance of the CMS cathode strip chambers with cosmic rays. in Journal of Instrumentation, 5. https://doi.org/10.1088/1748-0221/5/03/T03018
Chatrchyan S, Adžić P, Đorđević M, Jovanović DJ, Krpić D, Maletić D, Puzović JM, Smiljković N, Milenović P. Performance of the CMS cathode strip chambers with cosmic rays. in Journal of Instrumentation. 2010;5. doi:10.1088/1748-0221/5/03/T03018 .
Chatrchyan, S., Adžić, Petar, Đorđević, Miloš, Jovanović, Dragana J., Krpić, D., Maletić, Dimitrije, Puzović, Jovan M., Smiljković, Nikola, Milenović, Predrag, "Performance of the CMS cathode strip chambers with cosmic rays" in Journal of Instrumentation, 5 (2010), https://doi.org/10.1088/1748-0221/5/03/T03018 . .