dc.description.abstractA comparison of experimental and calculated responses of a CR-39 detector to neutron spectra from an Am-Be source is presented. Code named Neutron_CR-39.F90 has been used to calculate the neutron dose equivalent as well as the track density. Conversion coefficient (sensitivity), between track density in track/cm(2) and neutron dose equivalent in mSv, was calculated and good agreement with experimental data was found. Sensitivity increases linearly with removed layer in the range between 6 mu m and 24 mu m. (C) 2014 Elsevier Ltd. All rights reserved.en
dc.relationinfo:eu-repo/grantAgreement/MESTD/Basic Research (BR or ON)/171021/RS//
dc.rightsrestrictedAccessen
dc.sourceApplied Radiation and Isotopesen
dc.subjectNeutronen
dc.subjectCR-39en
dc.subjectMonte Carlo simulationen
dc.subjectChemical etchingen
dc.subjectProton tracken
dc.titleDetermination of a CR-39 detector response to neutrons from an Am-Be sourceen
dc.typearticleen
dcterms.abstractНикезиц, Д.; Косутиц, Д.; Стевановиц, Н.; Миленковиц, Б.;
dc.citation.volume90
dc.citation.spage225
dc.citation.epage228
dc.identifier.wos000347596400034
dc.identifier.doi10.1016/j.apradiso.2014.04.008