Приказ основних података о документу

dc.creatorAteia, Embarka
dc.creatorCiraj-Bjelac, Olivera
dc.creatorKovačević, Milojko
dc.creatorBeličev, Petar
dc.creatorCvetković, Bratislav
dc.creatorAničin, Ivan V.
dc.date.accessioned2018-03-01T20:08:24Z
dc.date.available2018-03-01T20:08:24Z
dc.date.issued2008
dc.identifier.issn1451-3994
dc.identifier.urihttps://vinar.vin.bg.ac.rs/handle/123456789/3244
dc.description.abstractIt is well known that medical linear accelerators generate activation products when operated above certain electron (photon) energies. The aim of the present work is to assess the activation behavior of a medium-energy radiotherapy linear accelerator by applying in situ gamma-ray spectrometry and dose measurements, and to estimate the additional dose to radiotherapy staff on the basis of these results. Spectral analysis was performed parallel to dose rate measurements in the isocenter of the linear accelerator, immediately after the termination of irradiation. The following radioisotopes were detected by spectral analysis: (28)Al, (62)Cu, (56)Mn, (64)Cu, (187)W, and (57)Ni. The short-lived isotopes such as (28)Al and (62)Cu are the most important factors of the clinical routine, while the contribution to the radiation dose of medium-lived isotopes such as (56)Mn, (57)Ni, (64)Cu, and (187)W increases during the working day. Measured dose rates at the isocenter ranged from 2.2 mu Sv/h to 10 mu Sv/h in various measuring points of interest for the members of the radiotherapy staff. Within the period of 10 minutes, the dose rate decreased to values of 0.8 mu Sv/h. According to actual workloads in radiotherapy departments, a realistic exposure scenario was set, resulting in a maximal additional annual whole body dose to the radiotherapy staff of about 3.5 mSv.en
dc.relationSerbian Ministry of Sciences [1410413]
dc.rightsopenAccessen
dc.sourceNuclear technology and radiation protectionen
dc.subjectlinear acceleratorsen
dc.subjectactivationen
dc.subjectradioisotopesen
dc.subjectphotonuclear reactionen
dc.subjectgamma spectroscopyen
dc.titleAdditional Dose Assessment from the Activation of High-Energy Linear Accelerators Used in Radiation Therapyen
dc.typearticleen
dcterms.abstractAтеиа, Ембарка; Цветковиц, Братислав; Цирај-Бјелац Оливера; Ковацевић Милојко; Беличев Петар; Aничин Иван В;
dc.citation.volume23
dc.citation.issue2
dc.citation.spage58
dc.citation.epage64
dc.identifier.wos000262142600009
dc.identifier.doi10.2298/NTRP0802058A
dc.identifier.scopus2-s2.0-77955609516
dc.identifier.fulltexthttps://vinar.vin.bg.ac.rs//bitstream/id/12415/3240.pdf


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу