Приказ основних података о документу

dc.creatorZigic, A
dc.creatorAranđelović, Vojislav
dc.date.accessioned2018-03-01T19:43:25Z
dc.date.available2018-03-01T19:43:25Z
dc.date.issued2006
dc.identifier.issn1350-4487
dc.identifier.urihttps://vinar.vin.bg.ac.rs/handle/123456789/2951
dc.description.abstractTwo methods developed to improve the classical time constant count rate meters by using the adaptive signal-processing tools are presented. An optimized detection algorithm that senses the change of the mean count rate was implemented in both methods. Three different types of low-pass filters of various structures with adaptive parameters to implement the control of the mean count rate error by suppressing the fluctuations in a controllable way were considered, and one of them was implemented in both methods. An adaptation algorithm for time constant interval calculation was executed after the low-pass filter was devised and implemented in the first method. This adaptation algorithm makes it possible to obtain shorter time constant intervals for higher stationary mean count rates. The adaptation algorithm for time constant interval calculation executed before the low-pass filter was devised and implemented in the second method. This adaptation algorithm enables sensing of the rapid change of the mean count rate before the fluctuations suppression is carried out. Some parameters were fixed to their optimum values after appropriate optimization procedures had been performed. The implemented low-pass filter has variable number of stationary coefficients depending on the specified error and the mean count rate. It implements the control of the mean count rate error by suppressing the fluctuations in a controllable way. The simulated and realized methods, using the developed algorithms, guarantee: a response time not in excess of 2 s for a mean count rate higher than 2 counts/s and a controllable mean count rate error in the range of 4-10%. (c) 2005 Elsevier Ltd. All rights reserved.en
dc.rightsrestrictedAccessen
dc.sourceRadiation Measurementsen
dc.subjecttime constant count rate meteren
dc.subjectadaptive signal processingen
dc.subjectlow-pass filteren
dc.subjectFIR filteren
dc.subjectmean count rateen
dc.titleCount rate meter with a time constant using adaptive digital signal processingen
dc.typearticleen
dcterms.abstractЗигиц, A; Aрандјеловиц, В;
dc.citation.volume41
dc.citation.issue3
dc.citation.spage295
dc.citation.epage305
dc.identifier.wos000233857800007
dc.identifier.doi10.1016/j.radmeas.2005.08.001
dc.citation.rankM21
dc.identifier.scopus2-s2.0-27844473702