Low energy beam line at the AGOR facility
Апстракт
The origin of the low transmission through the low energy beam line between the electron cyclotron resonance source and the AGOR cyclotron has been investigated. Measurements of beam size and emittance, determined with the varying quadrupole method, are compared with calculations including fringe fields up to third order with the code COSY INFINITY. Calculations and measurements qualitatively agree; the calculations exhibit the large beam losses observed. On the basis of the calculations new settings have been determined, resulting in a significant increase of the transmission. To achieve full transmission a complete redesign of the beam line, in particular of the bending magnets, is needed. (C) 2005 American Institute of Physics.
Извор:
Review of Scientific Instruments, 2005, 76, 1
DOI: 10.1063/1.1823653
ISSN: 0034-6748
WoS: 000226738300008
Scopus: 2-s2.0-19744382767
Колекције
Институција/група
VinčaTY - JOUR AU - Toprek, Dragan AU - Formanoy, I AU - Brandenburg, S PY - 2005 UR - https://vinar.vin.bg.ac.rs/handle/123456789/2852 AB - The origin of the low transmission through the low energy beam line between the electron cyclotron resonance source and the AGOR cyclotron has been investigated. Measurements of beam size and emittance, determined with the varying quadrupole method, are compared with calculations including fringe fields up to third order with the code COSY INFINITY. Calculations and measurements qualitatively agree; the calculations exhibit the large beam losses observed. On the basis of the calculations new settings have been determined, resulting in a significant increase of the transmission. To achieve full transmission a complete redesign of the beam line, in particular of the bending magnets, is needed. (C) 2005 American Institute of Physics. T2 - Review of Scientific Instruments T1 - Low energy beam line at the AGOR facility VL - 76 IS - 1 DO - 10.1063/1.1823653 ER -
@article{ author = "Toprek, Dragan and Formanoy, I and Brandenburg, S", year = "2005", abstract = "The origin of the low transmission through the low energy beam line between the electron cyclotron resonance source and the AGOR cyclotron has been investigated. Measurements of beam size and emittance, determined with the varying quadrupole method, are compared with calculations including fringe fields up to third order with the code COSY INFINITY. Calculations and measurements qualitatively agree; the calculations exhibit the large beam losses observed. On the basis of the calculations new settings have been determined, resulting in a significant increase of the transmission. To achieve full transmission a complete redesign of the beam line, in particular of the bending magnets, is needed. (C) 2005 American Institute of Physics.", journal = "Review of Scientific Instruments", title = "Low energy beam line at the AGOR facility", volume = "76", number = "1", doi = "10.1063/1.1823653" }
Toprek, D., Formanoy, I.,& Brandenburg, S.. (2005). Low energy beam line at the AGOR facility. in Review of Scientific Instruments, 76(1). https://doi.org/10.1063/1.1823653
Toprek D, Formanoy I, Brandenburg S. Low energy beam line at the AGOR facility. in Review of Scientific Instruments. 2005;76(1). doi:10.1063/1.1823653 .
Toprek, Dragan, Formanoy, I, Brandenburg, S, "Low energy beam line at the AGOR facility" in Review of Scientific Instruments, 76, no. 1 (2005), https://doi.org/10.1063/1.1823653 . .