Приказ основних података о документу

dc.creatorĐolić, Maja B.
dc.creatorRajaković-Ognjanović, Vladana N.
dc.creatorŠtrbac, Svetlana
dc.creatorDimitrijević, Suzana I.
dc.creatorMitrić, Miodrag
dc.creatorOnjia, Antonije E.
dc.creatorRajaković, Ljubinka V.
dc.date.accessioned2018-03-01T17:50:51Z
dc.date.available2018-03-01T17:50:51Z
dc.date.issued2017
dc.identifier.issn1871-6784
dc.identifier.issn1876-4347
dc.identifier.urihttps://vinar.vin.bg.ac.rs/handle/123456789/1728
dc.description.abstractThe objective of this study was to investigate the modification of materials used in wastewater treatment for possible antimicrobial application(s). Granulated activated carbon (GAC) and natural clinoptilolite (CLI) were activated using Cu2+-and Zn2+-ions and the disinfection ability of the resulting materials was tested. Studies of the sorption and desorption kinetics were performed in order to determine and clarify the antimicrobial activity of the metal-activated sorbents. The exact sorption capacities of the selected sorbents, GAC and CLI, activated through use of Cu2+-ions, were 15.90 and 3.60 mg/g, respectively, while for the materials activated by Zn2+-ions, the corresponding capacities were 14.00 and 4.72 mg/g,. The desorption rates were 2 and 3 orders of magnitude lower than their sorption efficacy for the Cu2+-, and Zn2+-activated sorbents, respectively. The intermediate sorption capacity and low desorption rate indicated that the overall antimicrobial activity of the metal-modified sorbents was a result of metal ions immobilized onto surface sites. The effect of antimicrobial activity of free ions desorbed from the metal-activated surface may thus be disregarded. The antimicrobial activities of Cu/GAC, Zn/GAC, Cu/CLI and Zn/ CLI were also tested against Escherichia coli, Staphylococcus aureus, and Candida albicans. After 15 min exposure, the highest levels of cell inactivation were obtained through the Cu/CLI and the Cu/GAC against E. coli, 100.0 and 98.24%, respectively. However, for S. aureus and yeast cell inactivation, all Cu2+-and Zn2+-activated sorbents proved to be unsatisfactory. A characterization of the sorbents was performed by Xray diffraction (XRD), X-ray photo electron spectroscopy (XPS), and field emission scanning electron microscopy (FE-SEM). A concentration of the adsorbed and released ions was determined by inductively coupled plasma-optical emission spectroscopy (ICP-OES) and mass spectrometry (ICP-MS). The results showed that the antimicrobial performance of the activated sorbents depended on the surface characteristics of the material, which itself designates the distribution and the bioavailability of the activating agent. (C) 2017 Elsevier B. V. All rights reserved.en
dc.relationinfo:eu-repo/grantAgreement/MESTD/Integrated and Interdisciplinary Research (IIR or III)/43009/RS//
dc.relationCOST-European Cooperation in Science and Technology [1403, 1304]
dc.rightsrestrictedAccessen
dc.sourceNew Biotechnologyen
dc.subjectActivated sorbenten
dc.subjectAntimicrobial activityen
dc.subjectE. colien
dc.subjectS. aureusen
dc.subjectC. albicansen
dc.titleNatural sorbents modified by divalent Cu2+- and Zn2+- ions and their corresponding antimicrobial activityen
dc.typearticleen
dc.rights.licenseARR
dcterms.abstractРајаковиц-Огњановиц, Владана Н.; Ђолић Маја; Стрбац, Светлана Б.; Митрић Миодраг; Димитријевиц, Сузана И.; Оњиа, Aнтоније Е.; Рајаковиц, Љубинка В.;
dc.citation.volume39
dc.citation.spage150
dc.citation.epage159
dc.identifier.wos000410912900018
dc.identifier.doi10.1016/j.nbt.2017.03.001
dc.citation.otherPart number: A
dc.citation.rankM21
dc.identifier.pmid28263898
dc.type.versionpublishedVersion
dc.identifier.scopus2-s2.0-85015322654


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу