Improving gallic acid detection in plant samples: Fabrication and optimization of a sensitive and selective NiO-supported carbon paste electrode
Само за регистроване кориснике
2024
Аутори
Mutić, TijanaOgnjanović, Miloš
Ivković, Đurđa
Nikolić, Vladimir
Stanković, Vesna
Ristivojević, Petar
Stanković, Dalibor
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
In this study, we successfully prepared a modified nickel oxide (NiO) carbon paste electrode to detect gallic acid (GA). NiO nanoparticles were synthesized by the simple, organic solvent-free chemical coprecipitation method, and the electrochemical properties of the electrode and GA were thoroughly investigated using CV, SWV, and EIS, while morphological properties were examined using ICP-OES, TEM, SEM, and XRD. Excellent catalytic characteristics are displayed by the developed material which facilitates the interaction of the target with the electrode surface. The obtained electrochemical information showed that the incorporation of NiO nanoparticles to the carbon paste electrode effectively facilitates electron transfer processes and enriches the catalytic response of the carbon paste electrode. The fabricated NiO/CPE sensor showed a satisfactory linear relationship between peak current and GA concentration in the broad range of 0.2–100 μM and 100–200 μM with a low detection limit of... 0.04 μM and limit of quantification of 0.12 μM at pH 3 of BRBS as supporting electrolyte. The selectivity of the proposed method was satisfactory, with acceptable stability, considerable repeatability, and accurate reproducibility. Moreover, the good practicability performance could be effectuated at the NiO/CPE sensor for the quantitative analysis of GA in bourtree, walnut, primrose, and chamomile tea samples. The results were compared with the standard DPPH test and statistical processing of the results was performed, which confirmed the excellent agreement between the two methods. The developed method can provide a cost-effective, rapid, selective, and sensitive means for GA monitoring. When compared to other works, the developed technique has a wider linear range and lower LOD and LOQ, which makes this work a very important reference for the highly sensitive analysis of GA in the field of food safety.
Кључне речи:
Polyphenols / Electrochemical gallic acid sensor / Nickel oxide / Square wave voltammetryИзвор:
Journal of Electroanalytical Chemistry, 2024, 960, 118213-Финансирање / пројекти:
- Министарство науке, технолошког развоја и иновација Републике Србије, институционално финансирање - 200168 (Универзитет у Београду, Хемијски факултет) (RS-MESTD-inst-2020-200168)
- Министарство науке, технолошког развоја и иновација Републике Србије, институционално финансирање - 200288 (Иновациони центар Хемијског факултета у Београду доо) (RS-MESTD-inst-2020-200288)
- Министарство науке, технолошког развоја и иновација Републике Србије, институционално финансирање - 200026 (Универзитет у Београду, Институт за хемију, технологију и металургију - ИХТМ) (RS-MESTD-inst-2020-200026)
Колекције
Институција/група
VinčaTY - JOUR AU - Mutić, Tijana AU - Ognjanović, Miloš AU - Ivković, Đurđa AU - Nikolić, Vladimir AU - Stanković, Vesna AU - Ristivojević, Petar AU - Stanković, Dalibor PY - 2024 UR - https://vinar.vin.bg.ac.rs/handle/123456789/13031 AB - In this study, we successfully prepared a modified nickel oxide (NiO) carbon paste electrode to detect gallic acid (GA). NiO nanoparticles were synthesized by the simple, organic solvent-free chemical coprecipitation method, and the electrochemical properties of the electrode and GA were thoroughly investigated using CV, SWV, and EIS, while morphological properties were examined using ICP-OES, TEM, SEM, and XRD. Excellent catalytic characteristics are displayed by the developed material which facilitates the interaction of the target with the electrode surface. The obtained electrochemical information showed that the incorporation of NiO nanoparticles to the carbon paste electrode effectively facilitates electron transfer processes and enriches the catalytic response of the carbon paste electrode. The fabricated NiO/CPE sensor showed a satisfactory linear relationship between peak current and GA concentration in the broad range of 0.2–100 μM and 100–200 μM with a low detection limit of 0.04 μM and limit of quantification of 0.12 μM at pH 3 of BRBS as supporting electrolyte. The selectivity of the proposed method was satisfactory, with acceptable stability, considerable repeatability, and accurate reproducibility. Moreover, the good practicability performance could be effectuated at the NiO/CPE sensor for the quantitative analysis of GA in bourtree, walnut, primrose, and chamomile tea samples. The results were compared with the standard DPPH test and statistical processing of the results was performed, which confirmed the excellent agreement between the two methods. The developed method can provide a cost-effective, rapid, selective, and sensitive means for GA monitoring. When compared to other works, the developed technique has a wider linear range and lower LOD and LOQ, which makes this work a very important reference for the highly sensitive analysis of GA in the field of food safety. T2 - Journal of Electroanalytical Chemistry T1 - Improving gallic acid detection in plant samples: Fabrication and optimization of a sensitive and selective NiO-supported carbon paste electrode VL - 960 SP - 118213 DO - 10.1016/j.jelechem.2024.118213 ER -
@article{ author = "Mutić, Tijana and Ognjanović, Miloš and Ivković, Đurđa and Nikolić, Vladimir and Stanković, Vesna and Ristivojević, Petar and Stanković, Dalibor", year = "2024", abstract = "In this study, we successfully prepared a modified nickel oxide (NiO) carbon paste electrode to detect gallic acid (GA). NiO nanoparticles were synthesized by the simple, organic solvent-free chemical coprecipitation method, and the electrochemical properties of the electrode and GA were thoroughly investigated using CV, SWV, and EIS, while morphological properties were examined using ICP-OES, TEM, SEM, and XRD. Excellent catalytic characteristics are displayed by the developed material which facilitates the interaction of the target with the electrode surface. The obtained electrochemical information showed that the incorporation of NiO nanoparticles to the carbon paste electrode effectively facilitates electron transfer processes and enriches the catalytic response of the carbon paste electrode. The fabricated NiO/CPE sensor showed a satisfactory linear relationship between peak current and GA concentration in the broad range of 0.2–100 μM and 100–200 μM with a low detection limit of 0.04 μM and limit of quantification of 0.12 μM at pH 3 of BRBS as supporting electrolyte. The selectivity of the proposed method was satisfactory, with acceptable stability, considerable repeatability, and accurate reproducibility. Moreover, the good practicability performance could be effectuated at the NiO/CPE sensor for the quantitative analysis of GA in bourtree, walnut, primrose, and chamomile tea samples. The results were compared with the standard DPPH test and statistical processing of the results was performed, which confirmed the excellent agreement between the two methods. The developed method can provide a cost-effective, rapid, selective, and sensitive means for GA monitoring. When compared to other works, the developed technique has a wider linear range and lower LOD and LOQ, which makes this work a very important reference for the highly sensitive analysis of GA in the field of food safety.", journal = "Journal of Electroanalytical Chemistry", title = "Improving gallic acid detection in plant samples: Fabrication and optimization of a sensitive and selective NiO-supported carbon paste electrode", volume = "960", pages = "118213", doi = "10.1016/j.jelechem.2024.118213" }
Mutić, T., Ognjanović, M., Ivković, Đ., Nikolić, V., Stanković, V., Ristivojević, P.,& Stanković, D.. (2024). Improving gallic acid detection in plant samples: Fabrication and optimization of a sensitive and selective NiO-supported carbon paste electrode. in Journal of Electroanalytical Chemistry, 960, 118213. https://doi.org/10.1016/j.jelechem.2024.118213
Mutić T, Ognjanović M, Ivković Đ, Nikolić V, Stanković V, Ristivojević P, Stanković D. Improving gallic acid detection in plant samples: Fabrication and optimization of a sensitive and selective NiO-supported carbon paste electrode. in Journal of Electroanalytical Chemistry. 2024;960:118213. doi:10.1016/j.jelechem.2024.118213 .
Mutić, Tijana, Ognjanović, Miloš, Ivković, Đurđa, Nikolić, Vladimir, Stanković, Vesna, Ristivojević, Petar, Stanković, Dalibor, "Improving gallic acid detection in plant samples: Fabrication and optimization of a sensitive and selective NiO-supported carbon paste electrode" in Journal of Electroanalytical Chemistry, 960 (2024):118213, https://doi.org/10.1016/j.jelechem.2024.118213 . .