Results of the 2015 national indoor radon intercomparison measurements in Serbia

Thumbnail
2016
Preuzimanje 🢃
bitstream_4908.pdf (347.7Kb)
Autori
Forkapic, Sofija
Bikit, Kristina
Arsić, Vesna
Ilić, Jovana
Pantelić, Gordana K.
Živanović, Miloš Z.
Članak u časopisu (Objavljena verzija)
Metapodaci
Prikaz svih podataka o dokumentu
Apstrakt
Results and conclusions of interlaboratory comparison of indoor radon in 2015 in Serbia are presented. The participants were three accredited laboratories from Serbia: Serbian Institute of Occupational Health Dr Dragomir Karajovic, Laboratory for Radioactivity and Dose Measurements at the Faculty of Sciences, University of Novi Sad and Radiation and Environmental Protection Department, Vinca Institute of Nuclear Science. The laboratories make use of the same method for radon measurement, using charcoal canisters according to US Environmental Protection Agency (EPA) protocol 520/5-87-005. Calibration of detection efficiency was performed using EPA radium standard. Radon activity concentrations were determined on the basis of the intensity of short-living radon daughters, Bi-214 and Pb-214, gamma lines. The results of intercomparison were evaluated by using the u-test, which was calculated according to the International Atomic Energy Agency criteria. In this paper, not only limitations b...ut also the advantages and possibilities of application of this method for measuring levels of human exposure to radon are discussed.

Ključne reči:
charcoal canisters / indoor radon / interlaboratory comparison
Izvor:
Nukleonika, 2016, 61, 3, 321-325
Finansiranje / projekti:
  • Biosensing tehnologije i globalni sistem za kontinuirana istraživanja i integrisano upravljanje ekosistemima (RS-MESTD-Integrated and Interdisciplinary Research (IIR or III)-43002)
  • Agency for Radiation Protection and Nuclear Safety of Serbia

DOI: 10.1515/nuka-2016-0053

ISSN: 0029-5922; 1508-5791

WoS: 000383833000015

Scopus: 2-s2.0-84990026554
[ Google Scholar ]
URI
https://vinar.vin.bg.ac.rs/handle/123456789/1249
Kolekcije
  • WoS Import
Institucija/grupa
Vinča
TY  - JOUR
AU  - Forkapic, Sofija
AU  - Bikit, Kristina
AU  - Arsić, Vesna
AU  - Ilić, Jovana
AU  - Pantelić, Gordana K.
AU  - Živanović, Miloš Z.
PY  - 2016
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/1249
AB  - Results and conclusions of interlaboratory comparison of indoor radon in 2015 in Serbia are presented. The participants were three accredited laboratories from Serbia: Serbian Institute of Occupational Health Dr Dragomir Karajovic, Laboratory for Radioactivity and Dose Measurements at the Faculty of Sciences, University of Novi Sad and Radiation and Environmental Protection Department, Vinca Institute of Nuclear Science. The laboratories make use of the same method for radon measurement, using charcoal canisters according to US Environmental Protection Agency (EPA) protocol 520/5-87-005. Calibration of detection efficiency was performed using EPA radium standard. Radon activity concentrations were determined on the basis of the intensity of short-living radon daughters, Bi-214 and Pb-214, gamma lines. The results of intercomparison were evaluated by using the u-test, which was calculated according to the International Atomic Energy Agency criteria. In this paper, not only limitations but also the advantages and possibilities of application of this method for measuring levels of human exposure to radon are discussed.
T2  - Nukleonika
T1  - Results of the 2015 national indoor radon intercomparison measurements in Serbia
VL  - 61
IS  - 3
SP  - 321
EP  - 325
DO  - 10.1515/nuka-2016-0053
ER  - 
@article{
author = "Forkapic, Sofija and Bikit, Kristina and Arsić, Vesna and Ilić, Jovana and Pantelić, Gordana K. and Živanović, Miloš Z.",
year = "2016",
abstract = "Results and conclusions of interlaboratory comparison of indoor radon in 2015 in Serbia are presented. The participants were three accredited laboratories from Serbia: Serbian Institute of Occupational Health Dr Dragomir Karajovic, Laboratory for Radioactivity and Dose Measurements at the Faculty of Sciences, University of Novi Sad and Radiation and Environmental Protection Department, Vinca Institute of Nuclear Science. The laboratories make use of the same method for radon measurement, using charcoal canisters according to US Environmental Protection Agency (EPA) protocol 520/5-87-005. Calibration of detection efficiency was performed using EPA radium standard. Radon activity concentrations were determined on the basis of the intensity of short-living radon daughters, Bi-214 and Pb-214, gamma lines. The results of intercomparison were evaluated by using the u-test, which was calculated according to the International Atomic Energy Agency criteria. In this paper, not only limitations but also the advantages and possibilities of application of this method for measuring levels of human exposure to radon are discussed.",
journal = "Nukleonika",
title = "Results of the 2015 national indoor radon intercomparison measurements in Serbia",
volume = "61",
number = "3",
pages = "321-325",
doi = "10.1515/nuka-2016-0053"
}
Forkapic, S., Bikit, K., Arsić, V., Ilić, J., Pantelić, G. K.,& Živanović, M. Z.. (2016). Results of the 2015 national indoor radon intercomparison measurements in Serbia. in Nukleonika, 61(3), 321-325.
https://doi.org/10.1515/nuka-2016-0053
Forkapic S, Bikit K, Arsić V, Ilić J, Pantelić GK, Živanović MZ. Results of the 2015 national indoor radon intercomparison measurements in Serbia. in Nukleonika. 2016;61(3):321-325.
doi:10.1515/nuka-2016-0053 .
Forkapic, Sofija, Bikit, Kristina, Arsić, Vesna, Ilić, Jovana, Pantelić, Gordana K., Živanović, Miloš Z., "Results of the 2015 national indoor radon intercomparison measurements in Serbia" in Nukleonika, 61, no. 3 (2016):321-325,
https://doi.org/10.1515/nuka-2016-0053 . .

DSpace software copyright © 2002-2015  DuraSpace
O repozitorijumu VinaR | Pošaljite zapažanja

re3dataOpenAIRERCUB
 

 

Kompletan repozitorijumGrupeAutoriNasloviTemeOva institucijaAutoriNasloviTeme

Statistika

Pregled statistika

DSpace software copyright © 2002-2015  DuraSpace
O repozitorijumu VinaR | Pošaljite zapažanja

re3dataOpenAIRERCUB