Energy, Angular and Dose-rate Dependence of the GM Survey Meter Response
Аутори
Kržanović, NikolaHaralambos Apostolakopoulos, Filip
Đaletić, Miloš
Živanović, Miloš
Stanković, Koviljka
Конференцијски прилог (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
—Survey meters represent common radiation protection instruments used for ambient monitoring. They estimate the effective dose of occupationally exposed personnel, by measuring the ambient dose equivalent. A performance testing of a Geiger-Müller tube-based survey meter was realized in this paper. The energy and the dose rate dependence were determined for different thicknesses of lead tube wrappings, in order to achieve the optimal energy compensation. The energy response for higher-energy photons slightly improved by applying these filters, while it significantly worsened for low-energy X-rays. The angular dependence was tested in terms of angular response and its symmetry for different radiation qualities.
Кључне речи:
ambient dose equivalent / angular response / dose rate dependence / energy compensation / survey meterИзвор:
IcETRAN 2018 : 5th International Conference on Electrical, Electronic and Computing Engineering; Proceedings book, 2018, 1008-1011Издавач:
- Belgrade : ETRAN Society
Финансирање / пројекти:
- Физички и функционални ефекти интеракције зрачења са електротехничким и биолошким системима (RS-MESTD-Basic Research (BR or ON)-171007)
- Нове технологије за мониторинг и заштиту животног окружења од штетних хемијских супстанци и радијационог оптерећења (RS-MESTD-Integrated and Interdisciplinary Research (IIR or III)-43009)
Колекције
Институција/група
VinčaTY - CONF AU - Kržanović, Nikola AU - Haralambos Apostolakopoulos, Filip AU - Đaletić, Miloš AU - Živanović, Miloš AU - Stanković, Koviljka PY - 2018 UR - https://vinar.vin.bg.ac.rs/handle/123456789/11918 AB - —Survey meters represent common radiation protection instruments used for ambient monitoring. They estimate the effective dose of occupationally exposed personnel, by measuring the ambient dose equivalent. A performance testing of a Geiger-Müller tube-based survey meter was realized in this paper. The energy and the dose rate dependence were determined for different thicknesses of lead tube wrappings, in order to achieve the optimal energy compensation. The energy response for higher-energy photons slightly improved by applying these filters, while it significantly worsened for low-energy X-rays. The angular dependence was tested in terms of angular response and its symmetry for different radiation qualities. PB - Belgrade : ETRAN Society C3 - IcETRAN 2018 : 5th International Conference on Electrical, Electronic and Computing Engineering; Proceedings book T1 - Energy, Angular and Dose-rate Dependence of the GM Survey Meter Response SP - 1008 EP - 1011 UR - https://hdl.handle.net/21.15107/rcub_vinar_11918 ER -
@conference{ author = "Kržanović, Nikola and Haralambos Apostolakopoulos, Filip and Đaletić, Miloš and Živanović, Miloš and Stanković, Koviljka", year = "2018", abstract = "—Survey meters represent common radiation protection instruments used for ambient monitoring. They estimate the effective dose of occupationally exposed personnel, by measuring the ambient dose equivalent. A performance testing of a Geiger-Müller tube-based survey meter was realized in this paper. The energy and the dose rate dependence were determined for different thicknesses of lead tube wrappings, in order to achieve the optimal energy compensation. The energy response for higher-energy photons slightly improved by applying these filters, while it significantly worsened for low-energy X-rays. The angular dependence was tested in terms of angular response and its symmetry for different radiation qualities.", publisher = "Belgrade : ETRAN Society", journal = "IcETRAN 2018 : 5th International Conference on Electrical, Electronic and Computing Engineering; Proceedings book", title = "Energy, Angular and Dose-rate Dependence of the GM Survey Meter Response", pages = "1008-1011", url = "https://hdl.handle.net/21.15107/rcub_vinar_11918" }
Kržanović, N., Haralambos Apostolakopoulos, F., Đaletić, M., Živanović, M.,& Stanković, K.. (2018). Energy, Angular and Dose-rate Dependence of the GM Survey Meter Response. in IcETRAN 2018 : 5th International Conference on Electrical, Electronic and Computing Engineering; Proceedings book Belgrade : ETRAN Society., 1008-1011. https://hdl.handle.net/21.15107/rcub_vinar_11918
Kržanović N, Haralambos Apostolakopoulos F, Đaletić M, Živanović M, Stanković K. Energy, Angular and Dose-rate Dependence of the GM Survey Meter Response. in IcETRAN 2018 : 5th International Conference on Electrical, Electronic and Computing Engineering; Proceedings book. 2018;:1008-1011. https://hdl.handle.net/21.15107/rcub_vinar_11918 .
Kržanović, Nikola, Haralambos Apostolakopoulos, Filip, Đaletić, Miloš, Živanović, Miloš, Stanković, Koviljka, "Energy, Angular and Dose-rate Dependence of the GM Survey Meter Response" in IcETRAN 2018 : 5th International Conference on Electrical, Electronic and Computing Engineering; Proceedings book (2018):1008-1011, https://hdl.handle.net/21.15107/rcub_vinar_11918 .