Comparison of the Angular Response of Thermoluminescent and Optically Stimulated Luminescent Personal Dosimeters
Апстракт
Determination of the angular dependence of thermoluminescent (TL) and optically stimulated luminescent (OSL) dosimeters is of great importance for their application in poly-energetic multidirectional photon radiation fields. In order to determine the angular dependence of the dosimeter responses for different photon energies, the dosimeters were mounted on an ISO water slab phantom, irradiated in two narrow beam X-ray qualities (N-40 and N-80) and in one gamma ray quality (S-Cs), defined in IAEA SRS 16. The angles of incidence ranged from 0° to 60°, with an increment of 20°. Two types of TL dosimeters were used: MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P) and one type of OSL dosimeters, InLight (Al2O3:C). The two types of TL dosimeters have shown a similar deviation from their 0° responses for all the used radiation qualities, while the OSL dosimeters have shown a greater deviation from the reference values for the gamma radiation quality.
Кључне речи:
Angular dependence / OSL dosimeters / TL dosimetersИзвор:
IcETRAN 2017 : 4th International Conference on Electrical, Electronic and Computing Engineering; Proceedings book, 2017Издавач:
- Belgrade : ETRAN Society
Финансирање / пројекти:
- Физички и функционални ефекти интеракције зрачења са електротехничким и биолошким системима (RS-MESTD-Basic Research (BR or ON)-171007)
- Нове технологије за мониторинг и заштиту животног окружења од штетних хемијских супстанци и радијационог оптерећења (RS-MESTD-Integrated and Interdisciplinary Research (IIR or III)-43009)
Колекције
Институција/група
VinčaTY - CONF AU - Haralambos Apostolakopoulos, Filip AU - Kržanović, Nikola AU - Perazić, Luka AU - Stanković, Koviljka PY - 2017 UR - https://vinar.vin.bg.ac.rs/handle/123456789/11914 AB - Determination of the angular dependence of thermoluminescent (TL) and optically stimulated luminescent (OSL) dosimeters is of great importance for their application in poly-energetic multidirectional photon radiation fields. In order to determine the angular dependence of the dosimeter responses for different photon energies, the dosimeters were mounted on an ISO water slab phantom, irradiated in two narrow beam X-ray qualities (N-40 and N-80) and in one gamma ray quality (S-Cs), defined in IAEA SRS 16. The angles of incidence ranged from 0° to 60°, with an increment of 20°. Two types of TL dosimeters were used: MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P) and one type of OSL dosimeters, InLight (Al2O3:C). The two types of TL dosimeters have shown a similar deviation from their 0° responses for all the used radiation qualities, while the OSL dosimeters have shown a greater deviation from the reference values for the gamma radiation quality. PB - Belgrade : ETRAN Society C3 - IcETRAN 2017 : 4th International Conference on Electrical, Electronic and Computing Engineering; Proceedings book T1 - Comparison of the Angular Response of Thermoluminescent and Optically Stimulated Luminescent Personal Dosimeters UR - https://hdl.handle.net/21.15107/rcub_vinar_11914 ER -
@conference{ author = "Haralambos Apostolakopoulos, Filip and Kržanović, Nikola and Perazić, Luka and Stanković, Koviljka", year = "2017", abstract = "Determination of the angular dependence of thermoluminescent (TL) and optically stimulated luminescent (OSL) dosimeters is of great importance for their application in poly-energetic multidirectional photon radiation fields. In order to determine the angular dependence of the dosimeter responses for different photon energies, the dosimeters were mounted on an ISO water slab phantom, irradiated in two narrow beam X-ray qualities (N-40 and N-80) and in one gamma ray quality (S-Cs), defined in IAEA SRS 16. The angles of incidence ranged from 0° to 60°, with an increment of 20°. Two types of TL dosimeters were used: MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P) and one type of OSL dosimeters, InLight (Al2O3:C). The two types of TL dosimeters have shown a similar deviation from their 0° responses for all the used radiation qualities, while the OSL dosimeters have shown a greater deviation from the reference values for the gamma radiation quality.", publisher = "Belgrade : ETRAN Society", journal = "IcETRAN 2017 : 4th International Conference on Electrical, Electronic and Computing Engineering; Proceedings book", title = "Comparison of the Angular Response of Thermoluminescent and Optically Stimulated Luminescent Personal Dosimeters", url = "https://hdl.handle.net/21.15107/rcub_vinar_11914" }
Haralambos Apostolakopoulos, F., Kržanović, N., Perazić, L.,& Stanković, K.. (2017). Comparison of the Angular Response of Thermoluminescent and Optically Stimulated Luminescent Personal Dosimeters. in IcETRAN 2017 : 4th International Conference on Electrical, Electronic and Computing Engineering; Proceedings book Belgrade : ETRAN Society.. https://hdl.handle.net/21.15107/rcub_vinar_11914
Haralambos Apostolakopoulos F, Kržanović N, Perazić L, Stanković K. Comparison of the Angular Response of Thermoluminescent and Optically Stimulated Luminescent Personal Dosimeters. in IcETRAN 2017 : 4th International Conference on Electrical, Electronic and Computing Engineering; Proceedings book. 2017;. https://hdl.handle.net/21.15107/rcub_vinar_11914 .
Haralambos Apostolakopoulos, Filip, Kržanović, Nikola, Perazić, Luka, Stanković, Koviljka, "Comparison of the Angular Response of Thermoluminescent and Optically Stimulated Luminescent Personal Dosimeters" in IcETRAN 2017 : 4th International Conference on Electrical, Electronic and Computing Engineering; Proceedings book (2017), https://hdl.handle.net/21.15107/rcub_vinar_11914 .