Time and position resolution of the scintillator strips for a muon system at future colliders
Abstract
Prototype scintilator + WLS strips with SiPM readout for a muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon per SiPM has been observed, as well as time resolution of 0.45 ns and position resolution along the strip of 7.7 cm. (C) 2016 Elsevier B.V. All rights reserved.
Keywords:
Linear Collider / Muon system / Scintillator / Position resolution / Time resolutionSource:
Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment, 2016, 823, 120-125Publisher:
- Elsevier
Funding / projects:
- Physics and Detector R&D in HEP Experiments (RS-171012)
- Ministry of Education and Science, National Research Center Kurchatov Institute (Russian Federation), Department of Energy (United States of America)
DOI: 10.1016/j.nima.2016.03.091
ISSN: 0168-9002; 1872-9576
WoS: 000374661600016
Scopus: 2-s2.0-84963627642
Collections
Institution/Community
VinčaTY - JOUR AU - Denisov, Dmitri AU - Evdokimov, Valery AU - Lukić, Strahinja PY - 2016 UR - https://vinar.vin.bg.ac.rs/handle/123456789/1036 AB - Prototype scintilator + WLS strips with SiPM readout for a muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon per SiPM has been observed, as well as time resolution of 0.45 ns and position resolution along the strip of 7.7 cm. (C) 2016 Elsevier B.V. All rights reserved. PB - Elsevier T2 - Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment T1 - Time and position resolution of the scintillator strips for a muon system at future colliders VL - 823 SP - 120 EP - 125 DO - 10.1016/j.nima.2016.03.091 ER -
@article{ author = "Denisov, Dmitri and Evdokimov, Valery and Lukić, Strahinja", year = "2016", abstract = "Prototype scintilator + WLS strips with SiPM readout for a muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon per SiPM has been observed, as well as time resolution of 0.45 ns and position resolution along the strip of 7.7 cm. (C) 2016 Elsevier B.V. All rights reserved.", publisher = "Elsevier", journal = "Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment", title = "Time and position resolution of the scintillator strips for a muon system at future colliders", volume = "823", pages = "120-125", doi = "10.1016/j.nima.2016.03.091" }
Denisov, D., Evdokimov, V.,& Lukić, S.. (2016). Time and position resolution of the scintillator strips for a muon system at future colliders. in Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment Elsevier., 823, 120-125. https://doi.org/10.1016/j.nima.2016.03.091
Denisov D, Evdokimov V, Lukić S. Time and position resolution of the scintillator strips for a muon system at future colliders. in Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. 2016;823:120-125. doi:10.1016/j.nima.2016.03.091 .
Denisov, Dmitri, Evdokimov, Valery, Lukić, Strahinja, "Time and position resolution of the scintillator strips for a muon system at future colliders" in Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment, 823 (2016):120-125, https://doi.org/10.1016/j.nima.2016.03.091 . .