Ilić, Radovan D.

Link to this page

Authority KeyName Variants
c236ca6f-ba77-45bc-9619-a9d322103817
  • Ilić, Radovan D. (2)
Projects
No records found.

Author's Bibliography

Monte Carlo SRNA-VOX code for 3D proton dose distribution in voxelized geometry using CT data

Ilić, Radovan D.; Spasić-Jokić, Vesna; Beličev, Petar; Dragovic, M

(2005)

TY  - JOUR
AU  - Ilić, Radovan D.
AU  - Spasić-Jokić, Vesna
AU  - Beličev, Petar
AU  - Dragovic, M
PY  - 2005
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/6497
AB  - This paper describes the application of the SRNA Monte Carlo package for proton transport simulations in complex geometry and different material compositions. The SRNA package was developed for 3D dose distribution calculation in proton therapy and dosimetry and it was based on the theory of multiple scattering. The decay of proton induced compound nuclei was simulated by the Russian MSDM model and our own using ICRU 63 data. The developed package consists of two codes: the SRNA-2KG, which simulates proton transport in combinatorial geometry and the SRNA-VOX, which uses the voxelized geometry using the CT data and conversion of the Hounsfields data to tissue elemental composition. Transition probabilities for both codes are prepared by the SRNADAT code. The simulation of the proton beam characterization by multi-layer Faraday cup, spatial distribution of positron emitters obtained by the SRNA-2KG code and intercomparison of computational codes in radiation dosimetry, indicate immediate application of the Monte Carlo techniques in clinical practice. In this paper, we briefly present the physical model implemented in the SRNA package, the ISTAR proton dose planning software, as well as the results of the numerical experiments with proton beams to obtain 3D dose distribution in the eye and breast tumour.
T2  - Physics in Medicine and Biology
T1  - Monte Carlo SRNA-VOX code for 3D proton dose distribution in voxelized geometry using CT data
VL  - 50
IS  - 5
SP  - 1011
EP  - 1017
DO  - 10.1088/0031-9155/50/5/023
ER  - 
@article{
author = "Ilić, Radovan D. and Spasić-Jokić, Vesna and Beličev, Petar and Dragovic, M",
year = "2005",
abstract = "This paper describes the application of the SRNA Monte Carlo package for proton transport simulations in complex geometry and different material compositions. The SRNA package was developed for 3D dose distribution calculation in proton therapy and dosimetry and it was based on the theory of multiple scattering. The decay of proton induced compound nuclei was simulated by the Russian MSDM model and our own using ICRU 63 data. The developed package consists of two codes: the SRNA-2KG, which simulates proton transport in combinatorial geometry and the SRNA-VOX, which uses the voxelized geometry using the CT data and conversion of the Hounsfields data to tissue elemental composition. Transition probabilities for both codes are prepared by the SRNADAT code. The simulation of the proton beam characterization by multi-layer Faraday cup, spatial distribution of positron emitters obtained by the SRNA-2KG code and intercomparison of computational codes in radiation dosimetry, indicate immediate application of the Monte Carlo techniques in clinical practice. In this paper, we briefly present the physical model implemented in the SRNA package, the ISTAR proton dose planning software, as well as the results of the numerical experiments with proton beams to obtain 3D dose distribution in the eye and breast tumour.",
journal = "Physics in Medicine and Biology",
title = "Monte Carlo SRNA-VOX code for 3D proton dose distribution in voxelized geometry using CT data",
volume = "50",
number = "5",
pages = "1011-1017",
doi = "10.1088/0031-9155/50/5/023"
}
Ilić, R. D., Spasić-Jokić, V., Beličev, P.,& Dragovic, M.. (2005). Monte Carlo SRNA-VOX code for 3D proton dose distribution in voxelized geometry using CT data. in Physics in Medicine and Biology, 50(5), 1011-1017.
https://doi.org/10.1088/0031-9155/50/5/023
Ilić RD, Spasić-Jokić V, Beličev P, Dragovic M. Monte Carlo SRNA-VOX code for 3D proton dose distribution in voxelized geometry using CT data. in Physics in Medicine and Biology. 2005;50(5):1011-1017.
doi:10.1088/0031-9155/50/5/023 .
Ilić, Radovan D., Spasić-Jokić, Vesna, Beličev, Petar, Dragovic, M, "Monte Carlo SRNA-VOX code for 3D proton dose distribution in voxelized geometry using CT data" in Physics in Medicine and Biology, 50, no. 5 (2005):1011-1017,
https://doi.org/10.1088/0031-9155/50/5/023 . .
6
6
10

Applications of Monte Carlo software package FOTELP in doseimetry and radiation protection

Stanković, Srboljub; Ilić, Radovan D.

(Belgrade : Sebian Academy of Science and Arts, 2002)

TY  - CONF
AU  - Stanković, Srboljub
AU  - Ilić, Radovan D.
PY  - 2002
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/6401
AB  - In this paper some of numerous applications of Monte Carlo software FOTELP package, in dosimetry and radiation. protection, as special domains of applied physic, are presented. It carried out conclusions suggesting whats it like the prospect of Monte Carlo technique regarding numerical experiments in medical physics and applied nuclear physics.
PB  - Belgrade : Sebian Academy of Science and Arts
C3  - Applied physics in Serbia - APS : 1st Conference Applied Physics in Serbia : Contributed papers and invited lectures abstracts
T1  - Applications of Monte Carlo software package FOTELP in doseimetry and radiation protection
SP  - 337
EP  - 340
UR  - https://hdl.handle.net/21.15107/rcub_vinar_6401
ER  - 
@conference{
author = "Stanković, Srboljub and Ilić, Radovan D.",
year = "2002",
abstract = "In this paper some of numerous applications of Monte Carlo software FOTELP package, in dosimetry and radiation. protection, as special domains of applied physic, are presented. It carried out conclusions suggesting whats it like the prospect of Monte Carlo technique regarding numerical experiments in medical physics and applied nuclear physics.",
publisher = "Belgrade : Sebian Academy of Science and Arts",
journal = "Applied physics in Serbia - APS : 1st Conference Applied Physics in Serbia : Contributed papers and invited lectures abstracts",
title = "Applications of Monte Carlo software package FOTELP in doseimetry and radiation protection",
pages = "337-340",
url = "https://hdl.handle.net/21.15107/rcub_vinar_6401"
}
Stanković, S.,& Ilić, R. D.. (2002). Applications of Monte Carlo software package FOTELP in doseimetry and radiation protection. in Applied physics in Serbia - APS : 1st Conference Applied Physics in Serbia : Contributed papers and invited lectures abstracts
Belgrade : Sebian Academy of Science and Arts., 337-340.
https://hdl.handle.net/21.15107/rcub_vinar_6401
Stanković S, Ilić RD. Applications of Monte Carlo software package FOTELP in doseimetry and radiation protection. in Applied physics in Serbia - APS : 1st Conference Applied Physics in Serbia : Contributed papers and invited lectures abstracts. 2002;:337-340.
https://hdl.handle.net/21.15107/rcub_vinar_6401 .
Stanković, Srboljub, Ilić, Radovan D., "Applications of Monte Carlo software package FOTELP in doseimetry and radiation protection" in Applied physics in Serbia - APS : 1st Conference Applied Physics in Serbia : Contributed papers and invited lectures abstracts (2002):337-340,
https://hdl.handle.net/21.15107/rcub_vinar_6401 .
1