Specific heat and electrical resistivity of 53%Niobium-47%Titanium alloy measured by subsecond calorimetric technique
Апстракт
This paper presents results of measurements of the specific heat and electrical resistivity of a 53%Ni-47%Ti superconducting alloy. Both properties were measured by a contact variant of the millisecond-resolution pulse calorimeter. W5%Re/W25%Re thermocouple thermometry enabled study from ambient temperature to 2000 K. Results are discussed, and their uncertainty is estimated.
Кључне речи:
electric conductors / electrical resistivity / high temperatures / niobium titanium alloy / specific heat capacityИзвор:
International Journal of Thermophysics, 2002, 23, 5, 1319-1325Напомена:
- 6th International Workshop on Subsecond Thermophysics, Sep 26-28, 2001, Austrian Foundry Res Inst, Leoben, Austria
DOI: 10.1023/A:1019812925066
ISSN: 0195-928X
WoS: 000177526100019
Scopus: 2-s2.0-11144355918
Колекције
Институција/група
VinčaTY - JOUR AU - Pavicic, DZ AU - Maglic, KD PY - 2002 UR - https://vinar.vin.bg.ac.rs/handle/123456789/6337 AB - This paper presents results of measurements of the specific heat and electrical resistivity of a 53%Ni-47%Ti superconducting alloy. Both properties were measured by a contact variant of the millisecond-resolution pulse calorimeter. W5%Re/W25%Re thermocouple thermometry enabled study from ambient temperature to 2000 K. Results are discussed, and their uncertainty is estimated. T2 - International Journal of Thermophysics T1 - Specific heat and electrical resistivity of 53%Niobium-47%Titanium alloy measured by subsecond calorimetric technique VL - 23 IS - 5 SP - 1319 EP - 1325 DO - 10.1023/A:1019812925066 ER -
@article{ author = "Pavicic, DZ and Maglic, KD", year = "2002", abstract = "This paper presents results of measurements of the specific heat and electrical resistivity of a 53%Ni-47%Ti superconducting alloy. Both properties were measured by a contact variant of the millisecond-resolution pulse calorimeter. W5%Re/W25%Re thermocouple thermometry enabled study from ambient temperature to 2000 K. Results are discussed, and their uncertainty is estimated.", journal = "International Journal of Thermophysics", title = "Specific heat and electrical resistivity of 53%Niobium-47%Titanium alloy measured by subsecond calorimetric technique", volume = "23", number = "5", pages = "1319-1325", doi = "10.1023/A:1019812925066" }
Pavicic, D.,& Maglic, K.. (2002). Specific heat and electrical resistivity of 53%Niobium-47%Titanium alloy measured by subsecond calorimetric technique. in International Journal of Thermophysics, 23(5), 1319-1325. https://doi.org/10.1023/A:1019812925066
Pavicic D, Maglic K. Specific heat and electrical resistivity of 53%Niobium-47%Titanium alloy measured by subsecond calorimetric technique. in International Journal of Thermophysics. 2002;23(5):1319-1325. doi:10.1023/A:1019812925066 .
Pavicic, DZ, Maglic, KD, "Specific heat and electrical resistivity of 53%Niobium-47%Titanium alloy measured by subsecond calorimetric technique" in International Journal of Thermophysics, 23, no. 5 (2002):1319-1325, https://doi.org/10.1023/A:1019812925066 . .