Performance and operation of the CMS electromagnetic calorimeter
2010
Аутори
Chatrchyan, S.Adžić, Petar
Đorđević, Miloš
Jovanović, Dragana J.
Krpić, D.
Maletić, Dimitrije
Puzović, Jovan M.
Smiljković, Nikola
Milenović, Predrag
(ukupan broj autora: 2424)
Чланак у часопису
Метаподаци
Приказ свих података о документуАпстракт
The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75 848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented.
Кључне речи:
Calorimeters / Large detector systems for particle and astroparticle physicsИзвор:
Journal of Instrumentation, 2010, 5Финансирање / пројекти:
- FMSR (Austria), FNRS (Belgium), FWO (Belgium), CNPq (Brazil), CAPES (Brazil), FAPERJ (Brazil), FAPESP (Brazil), MES (Bulgaria), CERN (China), CAS (China), MoST (China), NSFC (China), COLCIEN-CIAS (Colombia), MSES (Croatia), RPF (Cyprus), Academy of Sciences (Estonia), NICPB (Estonia), Academy of Finland, ME (Finland), HIP (Finland), CEA (France), CNRS/IN2P3 (France), BMBF, Germany, DFG (Germany), HGF (Germany), GSRT (Greece), OTKA (Hungary), NKTH (Hungary), DAE (India), DST (India), IPM (Iran), SFI (Ireland), INFN (Italy), NRF (Korea), LAS (Lithuania), CINVESTAV (Mexico), CONACYT (Mexico), SEP (Mexico), UASLP-FAI (Mexico), PAEC (Pakistan), SCSR (Poland), FCT (Portugal), JINR (Armenia), JINR (Belarus), JINR (Georgia), JINR (Ukraine), JINR (Uzbekistan), MST (Russia), MAE (Russia), MSTDS (Serbia), MICINN (Spain, CPAN (Spain), Swiss Funding Agencies (Switzerland), NSC (Taipei), TUBITAK (Turkey), TAEK (Turkey), STFC (United Kingdom), DOE (USA), NSF (USA), European Union, Leventis Foundation, A.P. Sloan Foundation, Alexander von Humboldt Foundation
DOI: 10.1088/1748-0221/5/03/T03010
ISSN: 1748-0221
WoS: 000280524100023
Scopus: 2-s2.0-79953281768
Колекције
Институција/група
VinčaTY - JOUR AU - Chatrchyan, S. AU - Adžić, Petar AU - Đorđević, Miloš AU - Jovanović, Dragana J. AU - Krpić, D. AU - Maletić, Dimitrije AU - Puzović, Jovan M. AU - Smiljković, Nikola AU - Milenović, Predrag PY - 2010 UR - https://vinar.vin.bg.ac.rs/handle/123456789/4068 AB - The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75 848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented. T2 - Journal of Instrumentation T1 - Performance and operation of the CMS electromagnetic calorimeter VL - 5 DO - 10.1088/1748-0221/5/03/T03010 ER -
@article{ author = "Chatrchyan, S. and Adžić, Petar and Đorđević, Miloš and Jovanović, Dragana J. and Krpić, D. and Maletić, Dimitrije and Puzović, Jovan M. and Smiljković, Nikola and Milenović, Predrag", year = "2010", abstract = "The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75 848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented.", journal = "Journal of Instrumentation", title = "Performance and operation of the CMS electromagnetic calorimeter", volume = "5", doi = "10.1088/1748-0221/5/03/T03010" }
Chatrchyan, S., Adžić, P., Đorđević, M., Jovanović, D. J., Krpić, D., Maletić, D., Puzović, J. M., Smiljković, N.,& Milenović, P.. (2010). Performance and operation of the CMS electromagnetic calorimeter. in Journal of Instrumentation, 5. https://doi.org/10.1088/1748-0221/5/03/T03010
Chatrchyan S, Adžić P, Đorđević M, Jovanović DJ, Krpić D, Maletić D, Puzović JM, Smiljković N, Milenović P. Performance and operation of the CMS electromagnetic calorimeter. in Journal of Instrumentation. 2010;5. doi:10.1088/1748-0221/5/03/T03010 .
Chatrchyan, S., Adžić, Petar, Đorđević, Miloš, Jovanović, Dragana J., Krpić, D., Maletić, Dimitrije, Puzović, Jovan M., Smiljković, Nikola, Milenović, Predrag, "Performance and operation of the CMS electromagnetic calorimeter" in Journal of Instrumentation, 5 (2010), https://doi.org/10.1088/1748-0221/5/03/T03010 . .