Performance of the CMS drift tube chambers with cosmic rays
Нема приказа
Аутори
Chatrchyan, S.Adžić, Petar
Đorđević, Miloš
Jovanović, Dragana J.
Krpić, D.
Maletić, Dimitrije
Puzović, Jovan M.
Smiljković, Nikola
Milenović, Predrag
(ukupan broj autora: 2426)
Чланак у часопису
Метаподаци
Приказ свих података о документуАпстракт
Studies of the performance of the CMS drift tube barrel muon system are described, with results based on data collected during the CMS Cosmic Run at Four Tesla. For most of these data, the solenoidal magnet was operated with a central field of 3.8 T. The analysis of data from 246 out of a total of 250 chambers indicates a very good muon reconstruction capability, with a coordinate resolution for a single hit of about 260 mu m, and a nearly 100% efficiency for the drift tube cells. The resolution of the track direction measured in the bending plane is about 1.8 mrad, and the efficiency to reconstruct a segment in a single chamber is higher than 99%. The CMS simulation of cosmic rays reproduces well the performance of the barrel muon detector.
Кључне речи:
Large detector systems for particle and astroparticle physics / Particle tracking detectors (Gaseous detectors)Извор:
Journal of Instrumentation, 2010, 5Финансирање / пројекти:
- FMSR (Austria), FNRS (Belgium), FWO (Belgium), CNPq (Brazil), CAPES (Brazil), FAPERJ (Brazil), FAPESP (Brazil), MES (Bulgaria), CERN, CAS (China), MoST (China), NSFC (China), COLCIENCIAS (Colombia), MSES (Croatia), RPF (Cyprus), Academy of Sciences (Estonia), NICPB (Estonia), Academy of Finland, ME (Finland), HIP (Finland), CEA (France), CNRS/IN2P3 (France), BMBF, Germany, DFG (Germany), HGF (Germany), GSRT (Greece), OTKA (Hungary), NKTH (Hungary), DAE (India), DST (India), IPM (Iran), SFI (Ireland), INFN (Italy), NRF (Korea), LAS (Lithuania), CINVESTAV (Mexico), CONACYT (Mexico), SEP (Mexico), UASLP-FAI (Mexico), PAEC (Pakistan), SCSR (Poland), FCT (Portugal), MST (Russia), MAE (Russia), MSTDS (Serbia), MICINN (Spain), CPAN (Spain), Swiss Funding Agencies (Switzerland), NSC (Taipei), TUBITAK (Turkey), TAEK (Turkey), STFC (United Kingdom), DOE (USA), NSF (USA), European Union, Leventis Foundation, A.P. Sloan Foundation, Alexander von Humboldt Foundation, JINR (Armenia), JINR (Belarus), JINR (Georgia), JINR (Ukraine), JINR (Uzbekistan)
DOI: 10.1088/1748-0221/5/03/T03015
ISSN: 1748-0221
WoS: 000280524100017
Scopus: 2-s2.0-84855497081
Колекције
Институција/група
VinčaTY - JOUR AU - Chatrchyan, S. AU - Adžić, Petar AU - Đorđević, Miloš AU - Jovanović, Dragana J. AU - Krpić, D. AU - Maletić, Dimitrije AU - Puzović, Jovan M. AU - Smiljković, Nikola AU - Milenović, Predrag PY - 2010 UR - https://vinar.vin.bg.ac.rs/handle/123456789/3950 AB - Studies of the performance of the CMS drift tube barrel muon system are described, with results based on data collected during the CMS Cosmic Run at Four Tesla. For most of these data, the solenoidal magnet was operated with a central field of 3.8 T. The analysis of data from 246 out of a total of 250 chambers indicates a very good muon reconstruction capability, with a coordinate resolution for a single hit of about 260 mu m, and a nearly 100% efficiency for the drift tube cells. The resolution of the track direction measured in the bending plane is about 1.8 mrad, and the efficiency to reconstruct a segment in a single chamber is higher than 99%. The CMS simulation of cosmic rays reproduces well the performance of the barrel muon detector. T2 - Journal of Instrumentation T1 - Performance of the CMS drift tube chambers with cosmic rays VL - 5 DO - 10.1088/1748-0221/5/03/T03015 ER -
@article{ author = "Chatrchyan, S. and Adžić, Petar and Đorđević, Miloš and Jovanović, Dragana J. and Krpić, D. and Maletić, Dimitrije and Puzović, Jovan M. and Smiljković, Nikola and Milenović, Predrag", year = "2010", abstract = "Studies of the performance of the CMS drift tube barrel muon system are described, with results based on data collected during the CMS Cosmic Run at Four Tesla. For most of these data, the solenoidal magnet was operated with a central field of 3.8 T. The analysis of data from 246 out of a total of 250 chambers indicates a very good muon reconstruction capability, with a coordinate resolution for a single hit of about 260 mu m, and a nearly 100% efficiency for the drift tube cells. The resolution of the track direction measured in the bending plane is about 1.8 mrad, and the efficiency to reconstruct a segment in a single chamber is higher than 99%. The CMS simulation of cosmic rays reproduces well the performance of the barrel muon detector.", journal = "Journal of Instrumentation", title = "Performance of the CMS drift tube chambers with cosmic rays", volume = "5", doi = "10.1088/1748-0221/5/03/T03015" }
Chatrchyan, S., Adžić, P., Đorđević, M., Jovanović, D. J., Krpić, D., Maletić, D., Puzović, J. M., Smiljković, N.,& Milenović, P.. (2010). Performance of the CMS drift tube chambers with cosmic rays. in Journal of Instrumentation, 5. https://doi.org/10.1088/1748-0221/5/03/T03015
Chatrchyan S, Adžić P, Đorđević M, Jovanović DJ, Krpić D, Maletić D, Puzović JM, Smiljković N, Milenović P. Performance of the CMS drift tube chambers with cosmic rays. in Journal of Instrumentation. 2010;5. doi:10.1088/1748-0221/5/03/T03015 .
Chatrchyan, S., Adžić, Petar, Đorđević, Miloš, Jovanović, Dragana J., Krpić, D., Maletić, Dimitrije, Puzović, Jovan M., Smiljković, Nikola, Milenović, Predrag, "Performance of the CMS drift tube chambers with cosmic rays" in Journal of Instrumentation, 5 (2010), https://doi.org/10.1088/1748-0221/5/03/T03015 . .